Evidence map›Paper›PMID 37139767›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2023

[Modeling the noninvasive bi-level positive airway pressure ventilation therapy system and simulated application].

Yueyang Yuan, Li Zhou, Haoxuan Huang, Wei Liu, Xingshuo Hu, Lixin Xie

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. [Design and simulation study of positive pressure ventilation system in a simulated human biological lung].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Yueyang YuanThe Innovation Base of Diagnostic and Therapeutic Respiratory Equipment, Hunan City University, Yiyang, Hunan 413099, P. R. China.
Li ZhouThe Innovation Base of Diagnostic and Therapeutic Respiratory Equipment, Hunan City University, Yiyang, Hunan 413099, P. R. China.
Haoxuan HuangHunan Micomme Medical Development Co., Ltd, Changsha 410221, P. R. China.
Wei LiuHunan Micomme Medical Development Co., Ltd, Changsha 410221, P. R. China.
Xingshuo HuDepartment of Respiratory and Critical Care Medicine, Chinese PLA General Hospital, Beijing 100853, P. R. China.
Lixin XieDepartment of Respiratory and Critical Care Medicine, Chinese PLA General Hospital, Beijing 100853, P. R. China.
Changsha Medical University · CNChinese PLA General Hospital · CNHunan City University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Without artificial airway though oral, nasal or airway incision, the bi-level positive airway pressure (Bi-PAP) has been widely employed for respiratory patients. In an effort to investigate the therapeutic effects and measures for the respiratory patients under the noninvasive Bi-PAP ventilation, a therapy system model was designed for virtual ventilation experiments. In this system model, it includes a sub-model of noninvasive Bi-PAP respirator, a sub-model of respiratory patient, and a sub-model of the breath circuit and mask. And based on the Matlab Simulink, a simulation platform for the noninvasive Bi-PAP therapy system was developed to conduct the virtual experiments in simulated respiratory patient with no spontaneous breathing (NSB), chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). The simulated outputs such as the respiratory flows, pressures, volumes, etc, were collected and compared to the outputs which were obtained in the physical experiments with the active servo lung. By statistically analyzed with SPSS, the results demonstrated that there was no significant difference (

Indexed as

Positive-Pressure RespirationRespiration, ArtificialHumansLungRespirationVentilators, MechanicalBi-level pressureModel of therapy systemNoninvasive ventilationPositive airway pressureRespirator

Identifiers

PMID37139767
PMCPMC10162930
OpenAlexW4368358291

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.