Evidence map›Paper›PMID 37139764›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2023

[Application of automatic injection device based on automatic hemostasis in injection of radiopharmaceutical bolus injection].

Jin Li, Wenhong Fan, Jianxiong Ma, Wei Zhou, Xinxin Pang, Cungui Tian, Guohui Yang, Yan Wang, Na Zhao

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Application of micro-bolus injection and piezoelectric sensors to improve the safety of radiopharmaceuticals bolus injection].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jin LiTianjin Hospital, Tianjin University, Tianjin 300211, P. R. China.
Wenhong FanTianjin Medical University General Hospital, Tianjin 300052, P. R. China.
Jianxiong MaTianjin Hospital, Tianjin University, Tianjin 300211, P. R. China.
Wei ZhouCNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin 300300, P. R. China.
Xinxin PangCNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin 300300, P. R. China.
Cungui TianCNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin 300300, P. R. China.
Guohui YangCNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin 300300, P. R. China.
Yan WangTianjin Hospital, Tianjin University, Tianjin 300211, P. R. China.
Na ZhaoCNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin 300300, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In clinical practice, radiopharmaceutical dynamic imaging technology requires the bolus injection method to complete injection. Due to the failure rate and radiation damage of manual injection, even experienced technicians still bear a lot of psychological burden. This study combined the advantages and disadvantages of various manual injection modes to develop the radiopharmaceutical bolus injector, and explored the application of automatic injection in the field of bolus injection from four aspects: radiation protection, occlusion response, sterility of injection process and effect of bolus injection. Compared with the current mainstream manual injection method, the bolus manufactured by the radiopharmaceutical bolus injector based on the automatic hemostasis method had a narrower full width at half maximum and better repeatability. At the same time, radiopharmaceutical bolus injector had reduced the radiation dose of the technician's palm by 98.8%, and ensured more efficient vein occlusion recognition performance and sterility of the entire injection process. The radiopharmaceutical bolus injector based on automatic hemostasis has application potential in improving the effect and repeatability of bolus injection.

Indexed as

HandRadiopharmaceuticalsInjectionsRadiopharmaceuticalsAutomatic injection deviceBolus injectionRadiopharmaceutical dynamic imaging

Identifiers

PMID37139764
PMCPMC10162925

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.