ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2023
[Multiresolution discrete optimization registration method of ultrasound and magnetic resonance images based on key points].
Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- [A reweighted graph matching-based algorithm for automatic extraction of corresponding landmarks in medical images].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The registration of preoperative magnetic resonance (MR) images and intraoperative ultrasound (US) images is very important in the planning of brain tumor surgery and during surgery. Considering that the two-modality images have different intensity range and resolution, and the US images are degraded by lots of speckle noises, a self-similarity context (SSC) descriptor based on local neighborhood information was adopted to define the similarity measure. The ultrasound images were considered as the reference, the corners were extracted as the key points using three-dimensional differential operators, and the dense displacement sampling discrete optimization algorithm was adopted for registration. The whole registration process was divided into two stages including the affine registration and the elastic registration. In the affine registration stage, the image was decomposed using multi-resolution scheme, and in the elastic registration stage, the displacement vectors of key points were regularized using the minimum convolution and mean field reasoning strategies. The registration experiment was performed on the preoperative MR images and intraoperative US images of 22 patients. The overall error after affine registration was (1.57 ± 0.30) mm, and the average computation time of each pair of images was only 1.36 s; while the overall error after elastic registration was further reduced to (1.40 ± 0.28) mm, and the average registration time was 1.53 s. The experimental results show that the proposed method has prominent registration accuracy and high computational efficiency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.