Evidence map›Paper›PMID 37138577›Full record

ArticleFrontiers in pediatrics2023

Automated measurement of penile curvature using deep learning-based novel quantification method.

Sriman Bidhan Baray, Mohamed Abdelmoniem, Sakib Mahmud, Saidul Kabir, Md Ahasan Atick Faisal, Muhammad E H Chowdhury, Tariq O Abbas

Registry-linked trialAbstract read
In one paragraph

Article in Frontiers in pediatrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07017842 (PREDICT-H Study), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07017842 recruitingnot on this mapstarted 2025, after this paper: background citation

PREDICT-H Study: Prospective Research on Essential Determinants Influencing Complication Trends in Hypospadias - a Landmark Prospective Multicenter Cohort Study Aimed at Improving Outcome Prediction in Hypospadias Surgery

Typeobservational_patient_registrySponsorSidra MedicineRan2025 to 2028Enrolled1,300ConditionsHypospadias
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sriman Bidhan BarayDepartment of Electrical and Electronic Engineering, University of Dhaka, Dhaka, Bangladesh.
Mohamed AbdelmoniemDepartment of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar.
Sakib MahmudDepartment of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar.
Saidul KabirDepartment of Electrical and Electronic Engineering, University of Dhaka, Dhaka, Bangladesh.
Md Ahasan Atick FaisalDepartment of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar.
Muhammad E H ChowdhuryDepartment of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar.
Tariq O AbbasDepartment of Surgery, Weill Cornell Medicine-Qatar, Ar-Rayyan, Qatar.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Develop a reliable, automated deep learning-based method for accurate measurement of penile curvature (PC) using 2-dimensional images. Materials and methods: A set of nine 3D-printed models was used to generate a batch of 913 images of penile curvature (PC) with varying configurations (curvature range 18° to 86°). The penile region was initially localized and cropped using a YOLOv5 model, after which the shaft area was extracted using a UNet-based segmentation model. The penile shaft was then divided into three distinct predefined regions: the distal zone, curvature zone, and proximal zone. To measure PC, we identified four distinct locations on the shaft that reflected the mid-axes of proximal and distal segments, then trained an HRNet model to predict these landmarks and calculate curvature angle in both the 3D-printed models and masked segmented images derived from these. Finally, the optimized HRNet model was applied to quantify PC in medical images of real human patients and the accuracy of this novel method was determined. Results: We obtained a mean absolute error (MAE) of angle measurement <5° for both penile model images and their derivative masks. For real patient images, AI prediction varied between 1.7° (for cases of ∼30° PC) and approximately 6° (for cases of 70° PC) compared with assessment by a clinical expert. Discussion: This study demonstrates a novel approach to the automated, accurate measurement of PC that could significantly improve patient assessment by surgeons and hypospadiology researchers. This method may overcome current limitations encountered when applying conventional methods of measuring arc-type PC.

Indexed as

artificial intelligencechordeeHRNethypospadiasmachine learningpenile curvatureUNETYOLO

Identifiers

PMID37138577
PMCPMC10150132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.