Evidence map›Paper›PMID 37138237›Full record

ArticleBMC oral health2023

Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates.

Se-Hyang Kim, Sung-Min Lee, Jung-Hyun Park, Sook Yang, Jin-Woo Kim

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 2 pooled it
6.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Se-Hyang Kim *Graduate School of Clinical Dentistry, Ewha Womans University, Seoul, South Korea.
Sung-Min Lee *Department of Oral and Maxillofacial Surgery, School of Medicine, Ewha Womans University, Anyangcheon-Ro 1071, Yangcheon-Gu, Seoul, 158-710, Korea.
Jung-Hyun ParkGraduate School of Clinical Dentistry, Ewha Womans University, Seoul, South Korea.
Sook YangCusmedi Co., Ltd., Gyeonggi-Do, Suwon-Si, 400815, South Korea.
Jin-Woo KimGraduate School of Clinical Dentistry, Ewha Womans University, Seoul, South Korea. jinu600@gmail.com.
Ewha Womans University Medical Center · KREwha Womans University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputer-aided design/manufacturing (CAD/CAM) technology was developed to improve surgical accuracy and minimize errors in surgical planning and orthognathic surgery. However, its accurate implementation during surgery remains a challenge. Hence, we compared the accuracy and stability of conventional orthognathic surgery and the novel modalities, such as virtual simulation and three-dimensional (3D) titanium-printed customized surgical osteotomy guides and plates.

methodsThis prospective study included 12 patients who were willing to undergo orthognathic surgery. The study group consisted of patients who underwent orthognathic two-jaw surgery using 3D-printed patient-specific plates processed by selective laser melting and an osteotomy guide; orthognathic surgery was also performed by the surgeon directly bending the ready-made plate in the control group. Based on the preoperative computed tomography images and intraoral 3D scan data, a 3D virtual surgery plan was implemented in the virtual simulation module, and the surgical guide and bone fixation plate were fabricated. The accuracy and stability were evaluated by comparing the results of the preoperative virtual simulation (T0) to those at 7 days (T1) and 6 months (T2) post-surgery.

resultThe accuracy (ΔT1‒T0) and stability (ΔT2‒T1) measurements, using 11 anatomical references, both demonstrated more accurate results in the study group. The mean difference of accuracy for the study group (0.485 ± 0.280 mm) was significantly lower than in the control group (1.213 ± 0.716 mm) (P < 0.01). The mean operation time (6.83 ± 0.72 h) in the control group was longer than in the study group (5.76 ± 0.43 h) (P < 0.05).

conclusionThis prospective clinical study demonstrated the accuracy, stability, and effectiveness of using virtual preoperative simulation and patient-customized osteotomy guides and plates for orthognathic surgery.

Indexed as

Orthognathic SurgeryOrthognathic Surgical ProceduresComputer-Aided DesignHumansImaging, Three-DimensionalProspective StudiesTitaniumTitaniumComputer-aided surgical simulationOrthognathic surgeryPatient customized implantTitanium printingVirtual surgery

Identifiers

PMID37138237
PMCPMC10155400
OpenAlexW4368361364

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.