Evidence map›Paper›PMID 37137928›Full record

ArticleScientific reports2023

Machine learning based on computational fluid dynamics enables geometric design optimisation of the NeoVAD blades.

Lee Nissim, Shweta Karnik, P Alex Smith, Yaxin Wang, O Howard Frazier, Katharine H Fraser

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
16.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Lee NissimDepartment of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK.
Shweta KarnikInnovative Device and Engineering Applications (IDEA) Lab, Texas Heart Institute, Houston, Texas, 77030, USA.
P Alex SmithInnovative Device and Engineering Applications (IDEA) Lab, Texas Heart Institute, Houston, Texas, 77030, USA.
Yaxin WangInnovative Device and Engineering Applications (IDEA) Lab, Texas Heart Institute, Houston, Texas, 77030, USA.
O Howard FrazierInnovative Device and Engineering Applications (IDEA) Lab, Texas Heart Institute, Houston, Texas, 77030, USA.
Katharine H FraserDepartment of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK. k.h.fraser@bath.ac.uk.
University of Bath · GB

Funding

Development of a Fully-Implantable Ventricular Assist Device for Neonates and Children with Heart Failure - with Magnetic Levitation to Improve HemocompatibilityR01HL153538 · NHLBI · TEXAS HEART INSTITUTE · PI FRAZIER, O. H. · 2020 to 2023
$2.9M
NHLBI NIH HHS 1R01HL153538-01NHLBI NIH HHS R01 HL153538
6 · The paper itself

Abstract

The NeoVAD is a proposed paediatric axial-flow Left Ventricular Assist Device (LVAD), small enough to be implanted in infants. The design of the impeller and diffuser blades is important for hydrodynamic performance and haemocompatibility of the pump. This study aimed to optimise the blades for pump efficiency using Computational Fluid Dynamics (CFD), machine learning and global optimisation. Meshing of each design typically included 6 million hexahedral elements and a Shear Stress Transport turbulence model was used to close the Reynolds Averaged Navier-Stokes equations. CFD models of 32 base geometries, operating at 8 flow rates between 0.5 and 4 L/min, were created to match experimental studies. These were validated by comparison of the pressure-flow and efficiency-flow curves with those experimentally measured for all base prototype pumps. A surrogate model was required to allow the optimisation routine to conduct an efficient search; a multi-linear regression, Gaussian Process Regression and a Bayesian Regularised Artificial Neural Network predicted the optimisation objective at design points not explicitly simulated. A Genetic Algorithm was used to search for an optimal design. The optimised design offered a 5.51% increase in efficiency at design point (a 20.9% performance increase) as compared to the best performing pump from the 32 base designs. An optimisation method for the blade design of LVADs has been shown to work for a single objective function and future work will consider multi-objective optimisation.

Identifiers

PMID37137928
PMCPMC10156814
OpenAlexW4368362056

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.