Evidence map›Paper›PMID 37133560›Full record

ArticleInternational urogynecology journal2023

Could infiltration anesthesia decrease anchor-fixation quality of midurethral slings in the obturator complex?

Petr Kolek, Tereza Duchonova, Radek Sedlacek, Jaromir Masata

Abstract read
PubMed Publisher
In one paragraph

Article in International urogynecology journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Petr KolekDepartment of Obstetrics and Gynecology, 1st Medical Faculty, Charles University and General University Hospital in Prague, Prague, Czech Republic.
Tereza DuchonovaDepartment of Obstetrics and Gynecology, 1st Medical Faculty, Charles University and General University Hospital in Prague, Prague, Czech Republic.
Radek SedlacekLaboratory of Biomechanics, Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
Jaromir MasataDepartment of Obstetrics and Gynecology, 1st Medical Faculty, Charles University and General University Hospital in Prague, Prague, Czech Republic. masata@volny.cz.ORCID 0000-0002-3898-6608
Charles University · CZCzech Technical University in Prague · CZ

Funding

MH-CZ-DRO MH-CZ-DRO (General University Hospital in Prague - VFN, 00064165Univerzita Karlova v Praze UNCE 204024
6 · The paper itself

Abstract

introductionSingle-incision miduretral slings (SIMS) were withdrawn from the market in many countries due to lower efficacy. In some countries they are still in use, preferred primarily because it is possible to perform the procedure under local anesthesia. Based on our previous clinical experience we postulated that local anesthesia decreased primary anchor fixation in the obturator complex. The aim of the study is to assess how local infiltration anesthesia influences anchor fixation of the tape in porcine obturator complex.

methodsThe experiment was designed to determine the maximum force necessary to extract an implant anchor from a porcine obturator complex. The implant was extracted at a constant speed and data sampling frequency, and the data on displacement of the testing system, achieved force and time were recorded. The implant arms were divided into groups on the right and left sides. In the first group, the anchored arms were used for two implantations - primary and secondary without infiltration anesthesia - and in the second group they were used in the same way, using infiltration anesthesia.

resultsA total of 40 implanted anchors were tested in the experiment, totaling ten single-incision slings (each anchor was implanted twice). An average of 8.28 N (Newton) (SD 6.73, min. 2.11, max. 30.34 N) is required to remove the implant anchor from the obturator complex without infiltration by local anesthesia. An average force of 4.40 N (SD 2.99 min. 1.2, max. 9.48) is required to remove the anchor from the obturator complex after infiltration. Local anesthesia reduces anchor fixation in the obturator complex by 47%.

conclusionsThe local infiltrative anesthesia decreases anchor fixation in the porcine obturator complex.

Indexed as

Anesthesia, LocalSuburethral SlingsSuture AnchorsAnimalsFemaleSwineMidurethral sling (MUS)Obturator complexSingle-incision midurethral sling (SIMS)Stress urinary incontinenceTrans-obturator tape

Identifiers

PMID37133560
OpenAlexW4367834127

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.