ArticleProceedings of SPIE--the International Society for Optical Engineering2023
Optimizing data acquisition in undersampled magnetic resonance imaging (MRI) using two alternative forced choice (2-AFC) and search tasks.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Article
- Modeling human observer detection for varying data acquisition in undersampled MRI for two-alternative forced choice (2-AFC) and forced localization tasks.Proceedings of SPIE--the International Society for Optical Engineering · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Undersampling in the frequency domain (k-space) in MRI accelerates the data acquisition. Typically, a fraction of the low frequencies is fully collected and the rest are equally undersampled. We used a fixed 1D undersampling factor of 5x where 20% of the k-space lines are collected but varied the fraction of the low k-space frequencies that are fully sampled. We used a range of fully acquired low k-space frequencies from 0% where the primary artifact is aliasing to 20% where the primary artifact is blurring in the undersampling direction. Small lesions were placed in the coil k-space data for fluid-attenuated inversion recovery (FLAIR) brain images from the fastMRI database. The images were reconstructed using a multi-coil SENSE reconstruction with no regularization. We conducted a human observer two-alternative forced choice (2-AFC) study with a signal known exactly and a search task with variable backgrounds for each of the acquisitions. We found that for the 2-AFC task, the average human observer did better with more of the low frequencies being fully sampled. For the search task, we found that after an initial improvement from having none of the low frequencies fully sampled to just 2.5%, the performance remained fairly constant. We found that the performance in the two tasks had a different relationship to the acquired data. We also found that the search task was more consistent with common practice in MRI where a range of frequencies between 5% and 10% of the low frequencies are fully sampled.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.