Evidence map›Paper›PMID 37131176›Full record

ArticleBMC musculoskeletal disorders2023

Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty-a biomechanical in-vitro study.

Andrea Lorenz, Alexander Winter, Moritz Mederake, Clemens Freidhager, Ulf Krister Hofmann, Ulf Gunther Leichtle

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Trial
  2. Observational
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Andrea LorenzAustrian Center for Medical Innovation and Technology (ACMIT Gmbh), Wr. Neustadt, Austria.
Alexander WinterDepartment of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.
Moritz MederakeDepartment of Trauma and Reconstructive Surgery, BG Klinik, University of Tübingen, 72076, Tübingen, Germany. m.mederake@web.de.
Clemens FreidhagerInstitute for Lightweight Design and Computational Biomechanics, TU Wien, Vienna, Austria.
Ulf Krister HofmannDepartment of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.
Ulf Gunther LeichtleDepartment of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.
University Children's Hospital Tübingen · DETU Wien · ATBG Klinik Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAfter total knee arthroplasty, 10-30% of patients still complain about knee pain, even after exact positioning of the components. Altered knee kinematics are crucial in this regard. The aim of our study was to experimentally determine the influence of different degrees of component coupling of knee prostheses on joint kinematics during muscle-loaded knee flexion in-vitro.

methodsFemoral rollback and femoral rotation of a standard cruciate retaining (GCR), a posterior stabilized (GPS), a rotational hinge (RSL) and a total hinge (SSL) design of the same series of knee replacement implants (SL-series) of one single manufacturer (Waldemar Link GmbH, Hamburg, Germany) were analyzed and set in relation to the motion of the corresponding native knee in a paired study design. All different coupling degrees were analyzed in the same human knees. To simulate muscle loaded knee flexion, a knee simulator was used. Kinematics were measured with an ultrasonic motion capture system and integrated in a calculated coordinate system via CT-imaging.

resultsThe largest posterior motion on the lateral side was found for the native knee (8.7 ± 7.0 mm), followed by the GPS (3.2 ± 5.1 mm) and GCR (2.8 ± 7.3 mm) implants, while no motion was found for the RSL (0.1 ± 3.0 mm) and the SSL (-0.6 ± 2.7 mm) implants. In contrast, on the medial side, only the native knee showed a posterior motion (2.1 ± 3.2 mm). Regarding femoral external rotation, the only implant where the observed difference did not reach statistical significance when compared to the native knee was the GCR (p = 0.007).

conclusionThe GCR and GPS kinematics closely imitate those of the native joint. Medial femoral rollback is reduced, however, with the joint pivoting around a rotational center located in the medial plateau. Without additional rotational forces, the coupled RSL and SSL prostheses closely resemble each other with no femoral rollback or relevant rotational component. The femoral axis, however, shifts ventrally in both models when compared with their primary counterparts. The positioning of the coupling mechanism in the femoral and tibial component thus can already lead to altered joint kinematics even in prostheses with an identical surface geometry.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBiomechanical PhenomenaFemurHumansKnee JointProsthesis DesignRange of Motion, ArticularBiomechanicsFemoral rollbackHinged kneeKnee simulatorTotal knee arthroplasty

Identifiers

PMID37131176
PMCPMC10152755
OpenAlexW4367834865

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.