Evidence map›Paper›PMID 37130910›Full record

ArticleScientific reports2023

Implementing a velocity-based approach to resistance training: the reproducibility and sensitivity of different velocity monitoring technologies.

Ivan Jukic, Andrew King, Colby A Sousa, Katarina Prnjak, Michael R McGuigan

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Is the EnodeProSensors (Basel, Switzerland) · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Ivan JukicSport Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand. ivan.jukic@aut.ac.nz.ORCID 0000-0002-0900-9410
Andrew KingSport Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand.ORCID 0000-0002-9332-6506
Colby A SousaSport Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand.
Katarina PrnjakSchool of Medicine, Western Sydney University, Sydney, Australia.ORCID 0000-0002-6152-5025
Michael R McGuiganSport Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand.ORCID 0000-0002-1251-7838
Auckland University of Technology · NZWestern Sydney University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study examined the reproducibility of GymAware, PUSH2 and Vmaxpro velocity monitoring devices during resistance training (RT). The sensitivity of these devices to detect the smallest changes in velocity that correspond to true changes in RT performance was also investigated. Fifty-one resistance-trained men and women performed an incremental loading (1RM) test, and two repetitions to failure tests with different loads, 72 h apart. During all repetitions, mean velocity (MV) and peak velocity (PV) were simultaneously recorded by two devices of each brand. Overall, GymAware was the most reliable and sensitive device for detecting the smallest changes in RT performance, regardless of the velocity metric used. Vmaxpro can be considered as an equivalent, cheaper alternative to GymAware for RT monitoring and prescription, but only if the MV metric is used. Caution should be exercised when using PUSH2 in practice due to their comparatively higher, unacceptable measurement error and generally low sensitivity to detect changes in RT performance. Collectively, these findings support the use of MV and PV from GymAware and MV from Vmaxpro devices for RT monitoring and prescription due to their low magnitudes of error; thus, allowing for the detection of meaningful changes in neuromuscular status and functional performance during RT.

Indexed as

Resistance TrainingFemaleHumansMaleMuscle StrengthReproducibility of ResultsTransducersWeight Lifting

Identifiers

PMID37130910
PMCPMC10154341
OpenAlexW4367693983

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.