ArticleIEEE transactions on bio-medical engineering2023
A Concentric Tube Steerable Drilling Robot for Minimally Invasive Spinal Fixation of Osteoporotic Vertebrae.
Article in IEEE transactions on bio-medical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- A Synergistic Patient-Specific Approach for Enhanced Spinal Fixation Using a Novel Flexible Pedicle Screw and a Complementary Steerable Drilling Robotic System.IEEE transactions on bio-medical engineering · 2026Article
- Design and Validation of a Compact Concentric-Tube Robot for Percutaneous Nephrolithotomy.IEEE transactions on medical robotics and bionics · 2025Article
- Drilling around the corner: a comprehensive literature review of steerable bone drills.Frontiers in medical technology · 2025Review
- A Biomechanics-Aware Robot-Assisted Steerable Drilling Framework for Minimally Invasive Spinal Fixation Procedures.IEEE transactions on bio-medical engineering · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Spinal fixation with rigid pedicle screws have shown to be an effective treatment for many patients. However, this surgical option has been proved to be insufficient and will eventually fail for patients experiencing osteoporosis. This failure is mainly attributed to the lack of dexterity in the existing rigid drilling instruments and the complex anatomy of vertebrae, forcing surgeons to implant rigid pedicle screws within the osteoporotic regions of anatomy. To address this problem, in this article, we present the design, fabrication, and evaluation of a unique flexible yet structurally strong concentric tube steerable drilling robot (CT-SDR). The CT-SDR is capable of drilling smooth and accurate curved trajectories through hard tissues without experiencing buckling and failure; thus enabling the use of novel flexible pedicle screws for the next generation of spinal fixation procedures. Particularly, by decoupling the control of bending and insertion degrees of freedom (DoF) of the CT-SDR, we present a robotic system that (i) is intuitive to steer as it does not require an on-the-fly control algorithm for the bending DoF, and (ii) is able to address the contradictory requirements of structural stiffness and dexterity of a flexible robot interacting with the hard tissue. The robust and repeatable performance of the proposed CT-SDR have been experimentally evaluated by conducting various drilling procedures on simulated bone materials and animal bone samples. Experimental results indicate drilling times as low as 35 seconds for curved trajectories with 41 mm length and remarkable steering accuracy with a maximum 2% deviation error.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.