Evidence map›Paper›PMID 37129301›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2023

The effect of breast shielding outside the field of view on breast entrance surface dose in axial X-ray examinations: a phantom study.

Lauren Hurley, Yazeed Alashban, Salman Albeshan, Andrew England, Mark F McEntee

Open access · diamondAbstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 3 countries.

Lauren HurleyDepartment of Medical Imaging and Radiation Therapy, University College Cork, School of Medicine, Brookfield Health Sciences, Munster, Ireland.
Yazeed AlashbanDepartment of Radiological Sciences, King Saud University, College of Applied Medical Sciences, Riyadh, Saudi Arabia.ORCID 0000-0003-0857-524X
Salman AlbeshanDepartment of Radiological Sciences, King Saud University, College of Applied Medical Sciences, Riyadh, Saudi Arabia.ORCID 0000-0002-8612-1721
Andrew EnglandDepartment of Medical Imaging and Radiation Therapy, University College Cork, School of Medicine, Brookfield Health Sciences, Munster, Ireland.
Mark F McEnteeDepartment of Medical Imaging and Radiation Therapy, University College Cork, School of Medicine, Brookfield Health Sciences, Munster, Ireland.ORCID 0000-0001-7045-2190
University College Cork · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to evaluate the effect of outside-field-of-view (FOV) lead shielding on the entrance surface dose (ESD) of the breast on an anthropomorphic X-ray phantom for a variety of axial skeleton X-ray examinations.

methodsUsing an anthropomorphic phantom and radiation dosimeter, the ESD of the breast was measured with and without outside-FOV shielding in anterior-posterior (AP) abdomen, AP cervical spine, occipitomental 30° (OM30) facial bones, AP lumbar spine, and lateral lumbar spine radiography. The effect of several exposure parameters, including a low milliampere-seconds technique, grid use, automatic exposure control use, wraparound lead (WAL) use, trolley use, and X-ray table use, on the ESD of the breast with and without outside-FOV shielding was investigated. The mean ESD (μSv) and standard deviation for each radiographic protocol were calculated. A one-tailed Student's t-test was carried out to evaluate whether ESD to the breast was reduced with the use of outside-FOV shielding.

resultsA total of 920 breast ESD measurements were recorded across the different protocol parameters. The largest decrease in mean ESD of the breast with outside-FOV shielding was 0.002 μSv (

conclusionThis study found no significant decrease in the ESD of the breast with the use of outside-FOV shielding for the AP abdomen, AP cervical spine, OM30 facial bones, AP lumbar spine, or lateral lumbar spine radiography across a range of protocols.

Indexed as

Lumbar VertebraeThoraxHumansPhantoms, ImagingRadiation DosageRadiographyX-Raysanthropomorphic phantomentrance surface doseField of viewradiographyshieldingwraparound lead

Identifiers

PMID37129301
PMCPMC10679606
OpenAlexW4367668882

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.