ArticleAmerican journal of ophthalmology case reports2023
Intraocular lens tilt due to optic-haptic junction distortion following intrascleral haptic fixation with the Yamane technique.
Article in American journal of ophthalmology case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 26 citations in OpenAlex.
- A Novel Haptic Bending Technique to Correct Tilt after Flanged Intrascleral Intraocular Lens Fixation.Korean journal of ophthalmology : KJO · 2026Article
- Needle bevel-guided standardisation of scleral tunnel formation in intrascleral haptic fixation: a quantitative geometric analysis.BMC ophthalmology · 2026Article
- Refractive, visual, and safety outcomes of three surgical techniques for aphakia correction.Journal of cataract and refractive surgery · 2025Article
- Clinical impact of intraocular lens tilt and decentration: a cross-sectional study.BMC ophthalmology · 2025Article
- Severe intraocular lens tilt after the Yamane technique.Journal of cataract and refractive surgery · 2025Article
- Late Reverse Pupillary Block After Scleral Fixation With Yamane Technique: A Case Report.Case reports in ophthalmological medicine · 2025Article
- Recent advances and current challenges in suture and sutureless scleral fixation techniques for intraocular lens: a comprehensive review.Eye and vision (London, England) · 2024Review
- Safety and efficacy of the Yamane technique for intraocular three-piece lens implantation in Egyptian patients diagnosed with Marfan syndrome: a retrospective study.BMC ophthalmology · 2024Article
- Cross-Sectional Survey of Vitreoretinal Surgery Fellowship Training in Secondary Intraocular Lens Placement.Journal of vitreoretinal diseasesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To report two patients with a complication of Yamane intrascleral haptic fixation surgery (ISHF) with the Zeiss CT Lucia 602 lens: severely tilted intraocular lens (IOL) leading to significantly decreased vision in the early post-operative period. Observations: We report two patients presenting with severely tilted IOL implants one day and one month following Yamane ISHF. The first patient is a monocular 81-year-old woman referred for treatment of cornea edema. Initial surgery involved replacement of an anterior chamber lens with a CT Lucia 602 posterior chamber lens using Yamane technique and Descemet's stripping endothelial keratoplasty. The patient returned at one month follow-up with poor vision and IOL tilt observable at the slit lamp through a peripheral iridectomy site. Explanation of the Zeiss lens revealed haptic distortion at the optic-haptic insertion point such that each haptic was about 45° off axis to the plane of the optic in approximately equal and opposite directions. The second patient, a 75-year-old woman, was referred with a completely dislocated lens-bag complex in the right eye. The initial operative treatment for this patient included pars plana vitrectomy, retrieval and removal of the dislocated lens-bag complex, and placement of a Zeiss 602 lens via Yamane ISHF technique. On the first postoperative day, the patient was count fingers in the right eye with an intraocular pressure of 5 mm Hg and obvious IOL tilt on slit lamp examination. Explanation of the lens revealed severely distorted haptics relative to the optic by more than a 60-degree angle on both sides. In both cases, initial surgery was performed with an IOL inspected prior to implantation and found to have normal appearing haptics. At the end of each case, there was adequate centration and no tilt of the IOL. Management in both patients included removal of the defective lens and placement of a new, same power CT Lucia 602 lens via the Yamane technique. Visual acuity improved from CF to 20/30 best corrected after reoperation in both cases. Conclusions and importance: In summary, we describe a complication of Yamane ISHF with the CT Lucia 602 lens in which there is lens tilting associated with distortion at the optic-haptic fastening zone in the early postoperative period. In the event of a titled lens following Yamane ISHF, awareness of this complication may help surgeons consider lens replacement, as the haptics may be permanently distorted or damaged.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.