Evidence map›Paper›PMID 37125215›Full record

ArticleInternational journal of exercise science2023

Estimates of Agreement Between Three Low-cost and One High-cost Bioelectrical Impedance Analyzers using Classical and Contemporary Dancers.

Roberto González-Marenco, Martha Medina-Escobedo, Joaquín Blanco-Castillo, Jorge Euan-Zapata, Saile Chan-Kantún, José Sanguinó-Pinzon, Cinthia Gamboa-Pereyra

Open access · diamondAbstract read
In one paragraph

Article in International journal of exercise science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Roberto González-MarencoUniversidad Modelo, Mérida, Yucátan, MÉXICO.
Martha Medina-EscobedoHospital Regional de Alta Especialidad de la Península de Yucatán, MÉXICO.
Joaquín Blanco-CastilloClínica Hospital Mérida del ISSSTE, Yucatán, MÉXICO.
Jorge Euan-ZapataCliníca Salud Milenio, Mérida, Yucatán, MÉXICO.
Saile Chan-KantúnUniversidad Mesoamericana de San Agustín, Mérida, Yucatán, MÉXICO.
José Sanguinó-PinzonUniversidad Mesoamericana de San Agustín, Mérida, Yucatán, MÉXICO.
Cinthia Gamboa-PereyraUniversidad Modelo, Mérida, Yucátan, MÉXICO.
Universidad Mesoamericana de San Agustín · MXUniversidad Modelo · MXHospital Regional de Alta Especialidad del Bajío · MXSecretaría de Investigación, Innovación y Educación Superior · MXUniversidad Marista de Mérida · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to determine the concordance between the estimates of three low-cost and one high-cost electrical bioimpedance equipment (BIA) in classical and contemporary dancers. Participation in the study included 28 subjects (15 men and 13 women) 18 to 35 years old, who perform classical and/or modern dance, thrice weekly, from 60 to 120 min per session, for 10 years or more. Those who presented any disease, consumed drugs, supplements or multivitamins; had prostheses, surgical metal parts or pacemakers, had problems maintaining the correct anatomical positions for taking measurements, and pregnant women were excluded. Their body composition was determined with 3 low-cost BIA equipment (OMRON HBF-306C, SKULPT CHISEL and BEURER BF 1000) and one high-cost equipment (SECA mBCA 515). The results indicated that in men, SKULTP in its "complete" modality had the highest agreement with SECA (CCC=0.73, 95% CI=0.46-0.88) for body fat percentage (%BF); in women, OMRON in its "normal" modality had the highest agreement with SECA (CCC=0.85, 95% CI=0.62-0.94) for %BF; while BEURER had poor concordances (CCC=0.86-0.03) for the rest of the estimates in its different modalities, in both sexes. It is concluded that the lower cost equipment (SKULPT and OMRON) were the most consistent with SECA for %BF in normal weight dancers. BEURER had the lowest agreements with SECA, in all its modalities, as well as inconsistent estimates for all parameters. Therefore, there was no relationship between the cost of the low-cost impedance equipment and its agreement with those of a high-cost one.

Indexed as

bioimpedance equipmentBody compositionconcordancedancers

Identifiers

PMID37125215
PMCPMC10128120
OpenAlexW4367601640

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.