Evidence map›Paper›PMID 37125012›Full record

ArticleJournal of orthopaedics2023

Implant cost variation in surgically treated distal radius fractures.

Stephen A Doxey, Fernando A Huyke-Hernández, Jennifer L Robb, Deborah C Bohn, Brian P Cunningham

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06343467 (Generic Volar Locking Plate Use in Distal Radius Fractures), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06343467 nacompletednot on this map

Generic Volar Locking Plate Use in Distal Radius Fractures: A Prospective Randomized Study to Evaluate Clinical Outcomes and Cost Reduction

TypeinterventionalSponsorHealthPartners InstituteRan2022 to 2023Enrolled101ConditionsDistal Radius FracturesArmsGeneric Volar Locking Plate, Conventional Volar Locking Plate
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Stephen A DoxeyDepartment of Orthopaedic Surgery, Park Nicollet Methodist Hospital, St. Louis Park, MN, USA.
Fernando A Huyke-HernándezDepartment of Orthopaedic Surgery, Park Nicollet Methodist Hospital, St. Louis Park, MN, USA.
Jennifer L RobbDepartment of Orthopaedic Surgery, TRIA Orthopaedic Institute, Bloomington, MN, USA.
Deborah C BohnDepartment of Orthopaedic Surgery, TRIA Orthopaedic Institute, Bloomington, MN, USA.
Brian P CunninghamDepartment of Orthopaedic Surgery, Park Nicollet Methodist Hospital, St. Louis Park, MN, USA.
Park Nicollet Methodist Hospital · USTRIA Orthopaedic Center · USUniversity of Minnesota · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims & objectives: The purpose of this study was to evaluate for cost variation in distal radius fractures (DRFs) treated with a volar locking plate (VLP) and to identify key factors that affect the total construct cost. Materials & methods: A retrospective case series was conducted for a single healthcare system. A total of 140 patients with a DRF treated with a VLP from May 2014 to December 2021 were identified. Patients were excluded for polytrauma, open fractures, and skeletal immaturity. Results: Most patients were female (n = 120, 85.7%) and were on average 59 ± 13.7 years old. Patients most often injured their dominant hand (n = 75, 53.6%) and presented with an AO/OTA 23C fracture (n = 93, 66.4%). Twenty-two surgeons were included with fellowship training in hand or trauma and orthopaedic or plastic surgery residency. Orthopaedic hand-trained surgeons treated the highest proportion of 23C fractures (69.8%). Ninety patients (64.3%) were treated at a surgery center. The average cost was $1289.67 ± $215.32 (range: $857.83-$2156.95). The most expensive fixation constructs used a variable angle locking screw ($1316.75 ± $264.99) or a multidirectional threaded peg ($1321.67 ± $192.94). Multivariable regression analysis revealed none of the study variables to be significant contributors to construct cost (all p-values >0.27). Conclusions: Surgically treated DRFs with a VLP demonstrated similar total implant costs regardless of fracture pattern, surgeon specialty, or treatment facility. Contrary to previous literature, VLPs showed minimal cost variation, although some surgeons were able to decrease the overall cost by reducing the number of screws used.

Indexed as

Distal radius fracturesImplant costValue-based careVolar locking plate

Identifiers

PMID37125012
PMCPMC10139889
OpenAlexW4362696533

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.