Evidence map›Paper›PMID 37124554›Full record

ArticleHeart rhythm O22023

Transvenous lead extractions in a single high-volume center over a 24-year period: High success rate and low complication rate.

Thomas Morgan Knutsen, Per Torger Skretteberg, Paul Vanberg, Ziaullah Kamal, Sigrun Halvorsen, Knut Liestøl, Torkel Steen, Eivind Platou

Open access · goldAbstract read
In one paragraph

Article in Heart rhythm O2, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Thomas Morgan KnutsenDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Per Torger SkrettebergDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Paul VanbergDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Ziaullah KamalDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Sigrun HalvorsenDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Knut LiestølInstitute of Informatics, University of Oslo, Oslo, Norway.
Torkel SteenDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Eivind PlatouDepartment of Cardiology, Oslo University Hospital, Ullevaal, Oslo, Norway.
Oslo University Hospital · NOUniversity of Oslo · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transvenous lead extraction (TLE) procedures can be complicated and are associated with a small but significant risk of cardiovascular complications. However, methods and tools vary among centers. Objective: The purpose of this study was to the present the methods and results of pacemaker and implantable cardioverter-defibrillator TLE procedures in our center over a 24-year period. Methods: From April 1997 through 2020, we attempted to extract 2964 leads in 1780 procedures and 1642 patients. We mainly utilized single sheath technique using snaring or mechanical rotational sheaths and steel sheaths when necessary. Difficult procedures were performed by an experienced cardiologist, and close supervision was emphasized. Most of the extractions were performed using local anesthesia with sedation. Results: Median age of patients was 65.0 [interquartile range 20.00] years, and median dwelling time of leads was 5.0 [7.0] years. Clinical success was achieved in 1739 procedures (97.7%) and complete technical success in 2841 leads (95.8%). Clinical success (leaving <4 cm of the lead in the body and achieving the clinical goal for the patient) was achieved for 79 leads (2.7%). TLE failed in 44 leads (1.1%) and 41 procedures (2.3%) among 36 patients (2.2%). There were 23 cases (1.3%) of major complications, with only 1 death directly related to the procedure (<0.1%). In addition, 2 patients with sepsis died within the first 24 hours after the procedure. No caval tears occurred. Conclusion: Single sheath lead extractions utilizing snaring or mechanical rotational sheaths were effective and safe in our high-volume center as performed by experienced operators.

Indexed as

High-volume centerImplantable cardioverter-defibrillatorPacemakerSingle sheathTransvenous lead extraction

Identifiers

PMID37124554
PMCPMC10134393
OpenAlexW4317623055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.