Evidence map›Paper›PMID 37124529›Full record

ArticleFrontiers in oncology2023

Observation of the application effect of low-volume polyethylene glycol electrolyte lavage solution (PEG-ELS) combined with ascorbic acid tablets in bowel preparation for colonoscopy in hospitalized patients.

Le-Can Wu, En-Dian Zheng, Hao-Yue Sun, Xi-Zhou Lin, Ju-Yi Pan, Xiao-Xiao Lin

Open access · goldAbstract read
In one paragraph

Article in Frontiers in oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Le-Can WuDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
En-Dian ZhengDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
Hao-Yue SunDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
Xi-Zhou LinDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
Ju-Yi PanDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
Xiao-Xiao LinDepartment of Gastroenterology, Wenzhou People's Hospital, The Wenzhou Third Clinical Institute Affiliated to Wenzhou Medical University, Wenzhou, Zhejiang, China.
Wenzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study explored the effectiveness and safety of low-volume polyethylene glycol electrolyte lavage solution (PEG-ELS) combined with ascorbic acid tablets (PEG-ELS/Asc) in bowel preparation for a colonoscopy. Methods: A total of 240 hospitalized patients who underwent a colonoscopy in Wenzhou People's Hospital, Wenzhou Third Clinical College of Wenzhou Medical University from July 2020 to June 2022 were randomly divided into two groups, with 120 patients each. All of the participants were given a low-residue or residue-free diet one day before the examination and fasted after dinner (completed before 18:00) the day before the examination. The 2-L PEG-ELS/Asc group took 2-L PEG-ELS plus 10 g ascorbic acid tablets once orally, while the 3-L PEG-ELS group took 3-L PEG orally on several occasions. The primary endpoint was the achievement of preparation adequacy and an overall colon cleansing score of ≥6, both assessed by blinded investigators using the Boston Bowel Preparation Scale (BBPS). The bowel cleansing effect, polyp detection rate, adverse reaction rate, oral drug tolerance rate, renal function, and electrolyte level changes were also compared between the two patient groups. Results: There were no significant differences in the success rate of bowel preparation, the detection rate of polyps, or the adverse reaction rate between the two groups ( Conclusion: The effectiveness and safety of using 2-L PEG-ELS/Asc in bowel preparation for a colonoscopy in hospitalized patients were not inferior to using 3-L PEG-ELS. For patients with diabetes and constipation, the cleansing effect of the two bowel preparation options was not very satisfactory, and further clinical research is needed in this regard.

Indexed as

ascorbic acidbowel preparationcolonoscopycolorectal cancerpolyethylene glycol

Identifiers

PMID37124529
PMCPMC10141285
OpenAlexW4365513295

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.