Evidence map›Paper›PMID 37124108›Full record

ArticleBiomedical engineering letters2023

Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor.

Youjung Seo, Saehim Kwon, Unang Sunarya, Sungmin Park, Kwangsuk Park, Dawoon Jung, Youngho Cho, Cheolsoo Park

Open access · greenAbstract read
In one paragraph

Article in Biomedical engineering letters, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 3 countries.

Youjung Seo *Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea.
Saehim Kwon *Department of Artificial Intelligence, Kwangwoon University, Seoul, 01897 Korea.
Unang Sunarya *Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea.
Sungmin ParkDepartment of Convergence IT Engineering and the Department of Electrical Engineering, Pohang University of Science and Technology, Pohang, 37673 Korea.
Kwangsuk ParkDepartment of Biomedical Engineering, College of Medicine, Seoul National University, Seoul, 03080 Korea.
Dawoon JungCenter for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, 13916 Korea.
Youngho ChoDepartment of Electrical and Communication Engineering, University of Daelim, Anyang, 13916 Korea.
Cheolsoo ParkDepartment of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea.ORCID 0000-0001-8042-007X
Kwangwoon University · KRDaelim University College · KRKorea Institute of Science and Technology · KRPohang University of Science and Technology · KRSeoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rapid evolution of wearable technology in healthcare sectors has created the opportunity for people to measure their blood pressure (BP) using a smartwatch at any time during their daily activities. Several commercially-available wearable devices have recently been equipped with a BP monitoring feature. However, concerns about recalibration remain. Pulse transit time (PTT)-based estimation is required for initial calibration, followed by periodic recalibration. Recalibration using arm-cuff BP monitors is not practical during everyday activities. In this study, we investigated recalibration using PTT-based BP monitoring aided by a deep neural network (DNN) and validated the performance achieved with more practical wrist-cuff BP monitors. The PTT-based prediction produced a mean absolute error (MAE) of 4.746 ± 1.529 mmHg for systolic blood pressure (SBP) and 3.448 ± 0.608 mmHg for diastolic blood pressure (DBP) when tested with an arm-cuff monitor employing recalibration. Recalibration clearly improved the performance of both DNN and conventional linear regression approaches. We established that the periodic recalibration performed by a wrist-worn BP monitor could be as accurate as that obtained with an arm-worn monitor, confirming the suitability of wrist-worn devices for everyday use. This is the first study to establish the potential of wrist-cuff BP monitors as a means to calibrate BP monitoring devices that can reliably substitute for arm-cuff BP monitors. With the use of wrist-cuff BP monitoring devices, continuous BP estimation, as well as frequent calibrations to ensure accurate BP monitoring, are now feasible.

Indexed as

Attention mechanismBlood pressureDNNElectrocardiogramMAEPhotoplethysmogramRecalibrationSignal processing

Identifiers

PMID37124108
PMCPMC10130301
OpenAlexW4360617170

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.