Evidence map›Paper›PMID 37122941›Full record

ArticleIndian journal of anaesthesia2023

Comparison of C-MAC Miller blade video laryngoscope with conventional Miller blade in infants undergoing elective surgery- A prospective randomised trial.

Samriti Manhas, Nidhi Agrawal, Swati Jain, Ridhima Sharma, Ripon Choudhary

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of anaesthesia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 2 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 syntheses or guidelines pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Samriti ManhasDepartment of Anaesthesia and Critical Care, VMMC and Safdarjung Hospital, New Delhi, India.
Nidhi AgrawalDepartment of Anaesthesia and Critical Care, VMMC and Safdarjung Hospital, New Delhi, India.
Swati JainDepartment of Anaesthesia and Critical Care, Guru Teg Bahadur Hospital, Dilshad Garden, East, Delhi, India.
Ridhima SharmaDepartment of Anaesthesia and Critical Care, Maulana Azad Medical College and Lok Nayak Hospital, Bahadur Shah Zafar Marg, New Delhi, India.
Ripon ChoudharyDepartment of Anaesthesia and Critical Care, Maulana Azad Medical College and Lok Nayak Hospital, Bahadur Shah Zafar Marg, New Delhi, India.
Maulana Azad Medical College · INSafdarjang Hospital · INGuru Teg Bahadur Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Endotracheal intubation (ET) in infants is considered a challenging task over the decades. Infants have short safe apnoea time, and this difficulty has been vanquished to some extent by using the videolaryngoscopes (VLs), but there exists a dearth of research particularly in this vulnerable subset. Therefore, this trial was conducted to evaluate intubation times obtained with C-MAC VL and conventional Miller laryngoscopes in infants. Methods: A total of 80 infants aged between 1 month and 1 year with American Society of Anesthesiologists physical status I-II requiring ET were randomised in two groups; the C-MAC VL or Miller laryngoscope ML. Anaesthesia was induced with sevoflurane 1-8% and atracurium 0.5 mg/kg IV. The primary outcome was evaluated as the total time taken to intubate. Secondary outcomes were time to achieve best glottic view (TBGV), tube insertion time (TIT), percentage of glottic opening (POGO) score, number of attempts and intubation difficulty score (IDS). Results: The median (interquartile range) of time taken for ET was less in VL; 22.5 (20.75-26) compared to ML; 26 (21.75-31). TBGV was achieved early in VL group than the ML group (6.03 ± 1.33s/7.88 ± 2.44) respectively (P-value < 0.001). POGO was better in VL (99.12 ± 4.795s) compared to ML (85.50 ± 31.13s). IDS was less in the VL group (0.07 ± 0.27) than in ML (0.70 ± 1.14). Other parameters, such as the number of attempts, bougie usage, adverse effects and TIT, were comparable across the two groups. Conclusion: When compared to the ML group, the C-MAC VL group exhibited a decreased intubation time, early TBGV, better POGO score, reduced IDS and subjective intubation difficulty. As a result, we consider VL to be a more efficacious device for intubating the trachea in infants.

Indexed as

Infantintubationlaryngoscopestime

Identifiers

PMID37122941
PMCPMC10132685
OpenAlexW4321461707

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.