Evidence map›Paper›PMID 37122335›Full record

ArticleFrontiers in medicine2023

The endogenous thrombin potential in patients with left ventricular assist device or heart transplant.

Axel Schlagenhauf, Harald Haidl, Georg Trummer, Michael Berchtold-Herz, Jan-Steffen Pooth, Tanja Strini, Ulrich Geisen, Friedhelm Beyersdorf, Barbara Zieger

Open access · goldAbstract read
In one paragraph

Article in Frontiers in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Axel SchlagenhaufDepartment of Pediatrics and Adolescent Medicine, Division of General Pediatrics, Medical University Graz, Graz, Austria.
Harald HaidlDepartment of Pediatrics and Adolescent Medicine, Division of General Pediatrics, Medical University Graz, Graz, Austria.
Georg TrummerDepartment of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Michael Berchtold-HerzDepartment of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Jan-Steffen PoothDepartment of Emergency Medicine, Faculty of Medicine, Medical Center-University of Freiburg, Freiburg im Breisgau, Germany.
Tanja StriniDepartment of Pediatrics and Adolescent Medicine, Division of General Pediatrics, Medical University Graz, Graz, Austria.
Ulrich GeisenInstitute for Clinical Chemistry and Laboratory Medicine, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Friedhelm BeyersdorfDepartment of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Barbara ZiegerDepartment of Pediatrics and Adolescent Medicine, Division of Pediatric Hematology and Oncology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
University of Freiburg · DEMedical University of Graz · ATUniversitäts-Herzzentrum Freiburg-Bad Krozingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Heartmate 3 (HM 3) is a left ventricular assist device featuring less shear stress, milder acquired von Willebrand syndrome, and fewer bleeding incidences than its predecessor the Heartmate II (HM II). The novel surface coating of the HM 3 suggests less contact activation of plasmatic coagulation. We hypothesized that patients with HM 3 exhibit fewer aberrations in their thrombin potential than patients with HM II. We compared these results with the thrombin potential of patients with heart transplantation (HTX). Methods: Thrombin generation in plasma samples of patients with HM II ( Results: Three days postoperatively HM II patients exhibited a lower endogenous thrombin potential (ETP) than HM 3 and HTX patients (HM II: 947 ± 291 nM*min; HM 3: 1231 ± 176 nM*min; HTX: 1376 ± 162 nM*min, Conclusion: We observed a more aberrant thrombin generation in HM II than in HM 3 despite comparable anticoagulation and routine parameters. A trend toward lower values was still observable in HM 3 compared to HTX patients. Calibrated automated thrombography may be a good tool to monitor the coagulation state of these patients and guide anticoagulation in the future.

Indexed as

bleedingcoagulationHeartmateleft ventricular assist devicethrombin generation

Identifiers

PMID37122335
PMCPMC10130672
OpenAlexW4365149218

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.