Evidence map›Paper›PMID 37121949›Full record

ReviewEnvironmental science and pollution research international2023

Crosscutting of the pollutants and building ventilation systems: a literature review.

Amaia Zuazua-Ros, Leonardo de Brito Andrade, Sara Dorregaray-Oyaregui, César Martín-Gómez, Juan Carlos Ramos González, Robiel Manzueta, Bruno Sánchez Saiz-Ezquerra, Arturo H Ariño

Abstract readReview
In one paragraph

Review in Environmental science and pollution research international, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Amaia Zuazua-RosDepartment of Construction, Building Services and Structures, Universidad de Navarra, Campus Universitario, 31009, Pamplona, Spain.ORCID http://orcid.org/0000-0002-3065-1993
Leonardo de Brito AndradeDepartment of Rural Engineering, Center of Agrarian Sciences, Federal University of Santa Catarina, Rodovia Admar Gonzaga 1346, Florianópolis, SC, 88034-000, Brazil. leonardo.andrade@ufsc.br.ORCID http://orcid.org/0000-0003-0304-8838
Sara Dorregaray-OyareguiDepartment of Construction, Building Services and Structures, Universidad de Navarra, Campus Universitario, 31009, Pamplona, Spain.ORCID http://orcid.org/0000-0002-2930-7626
César Martín-GómezDepartment of Construction, Building Services and Structures, Universidad de Navarra, Campus Universitario, 31009, Pamplona, Spain.ORCID http://orcid.org/0000-0003-0150-1686
Juan Carlos Ramos GonzálezDepartment of Mechanical Engineering and Materials, Thermal and Fluids Engineering Division, Universidad de Navarra, Paseo de Manuel Lardizábal 13, 20018, San Sebastián, Spain.ORCID http://orcid.org/0000-0002-2560-1051
Robiel ManzuetaDepartment of Construction, Building Services and Structures, Universidad de Navarra, Campus Universitario, 31009, Pamplona, Spain.ORCID http://orcid.org/0000-0002-8195-5292
Bruno Sánchez Saiz-EzquerraDepartment of Construction, Building Services and Structures, Universidad de Navarra, Campus Universitario, 31009, Pamplona, Spain.ORCID http://orcid.org/0000-0001-6808-3314
Arturo H AriñoDepartment of Environmental Biology, Universidad de Navarra, Irunlarrea 1, 31008, Pamplona, Spain.ORCID http://orcid.org/0000-0003-4620-6445

Funding

Ministerio de Ciencia, Innovación y Universidades PID2019-104083RB-I00
6 · The paper itself

Abstract

Considering the time spent in enclosed environments, it is essential to study the relationship between pollutants and building ventilation systems to find whether the types and levels of pollutants and greenhouse gasses, which are expected to be exhaled through ventilation systems into the atmosphere, have been adequately evaluated. We propose the hypothesis that the exhaled air from residential buildings contains pollutants that may become another source of contamination affecting urban air quality and potentially contributing to climate drivers. Thus, the main goal of this article is to present a cross-review of the identification of pollutants expected to be exhaled through ventilation systems in residential buildings. This approach has created the concept of "exhalation of buildings" a new concept enclosed within the research project in which this article is included. We analyze the studies related to the most significant pollutants found in buildings and the studies about the relation of buildings' ventilation systems with such pollutants. Our results show that, on the one hand, the increase in the use of mechanical ventilation systems in residential buildings has been demonstrated to enhance the ventilation rate and generally improve the indoor air quality conditions. But no knowledge could be extracted about the corresponding environmental cost of this improvement, as no systematic data were found about the total mass of contaminants exhaled by those ventilation systems. At the same time, no projects were found that showed a quantitative study on exhalation from buildings, contrary to the existence of studies on pollutants in indoor air.

Indexed as

Air FiltersAir PollutantsAir Pollution, IndoorEnvironmental PollutantsAtmosphereClimateDrug ContaminationVentilationAir PollutantsEnvironmental PollutantsCitiesI/OAQMonitoringPollutant emissionsResidential buildingsUrbanVentilation systems

Identifiers

PMID37121949
PMCPMC10149636

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.