Improved visualization of the bone-implant interface and osseointegration in ex vivo acetabular cup implants using photon-counting detector CT.

Mischa Woisetschläger, Ronald Booij, Erik Tesselaar, Edwin H G Oei, Jörg Schilcher

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Higher bone cement volume in total knee arthroplasty lowers the risk of postoperative radiolucent lines.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Mischa Woisetschläger *Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. mischa.woisetschlager@liu.se.ORCID 0000-0003-0066-4985
Ronald Booij *Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Erik TesselaarCenter for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Edwin H G OeiDepartment of Radiology & Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands.
Jörg SchilcherCenter for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Linköping University · SEErasmus MC · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSuccessful osseointegration of joint replacement implants is required for long-term implant survival. Accurate assessment of osseointegration could enable clinical discrimination of failed implants from other sources of pain avoiding unnecessary surgeries. Photon-counting detector computed tomography (PCD-CT) provides improvements in image resolution compared to conventional energy-integrating detector CT (EID-CT), possibly allowing better visualization of bone-implant-interfaces and osseointegration. The aim of this study was to assess the quality of visualization of bone-implant-interfaces and osseointegration in acetabular cup implants, using PCD-CT compared with EID-CT.

methodsTwo acetabular implants (one cemented, one uncemented) retrieved during revision surgery were scanned using PCD-CT and EID-CT at equal radiation dose. Images were reconstructed using different reconstruction kernels and iterative strengths. Delineation of the bone-implant and bone-cement-interface as an indicator of osseointegration was scored subjectively for image quality by four radiologists on a Likert scale and assessed quantitatively.

resultsDelineation of bone-implant and bone-cement-interfaces was better with PCD-CT compared with EID-CT (p ≤ 0.030). The highest ratings were given for PCD-CT at sharper kernels for the cemented cup (PCD-CT, median 5, interquartile range 4.25-5.00 versus EID-CT, 3, 2.00-3.75, p < 0.001) and the uncemented cup (5, 4.00-5.00 versus 2, 2-2, respectively, p < 0.001). The bone-implant-interface was 35-42% sharper and the bone-cement-interface was 28-43% sharper with PCD-CT compared with EID-CT, depending on the reconstruction kernel.

conclusionsPCD-CT might enable a more accurate assessment of osseointegration of orthopedic joint replacement implants. KEY POINTS: • The bone-implant interface ex vivo showed superior visualization using photon-counting detector computed tomography (PCD-CT) compared to energy-integrating detector computed tomography. • Harder reconstruction kernels in PCD-CT provide sharper images with lower noise levels. • These improvements in imaging might make it possible to visualize osseointegration in vivo.

Indexed as

Bone-Implant InterfaceOsseointegrationPhantoms, ImagingPhotonsTomography, X-Ray ComputedArthroplastyJoint prosthesisOsseointegrationOsteoarthritis (hip)Tomography (x-ray computed)

Identifiers

PMID37121937
PMCPMC10149426
OpenAlexW4367556583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.