Evidence map›Paper›PMID 37117176›Full record

ArticleNature communications2023

Quantum microscopy of cells at the Heisenberg limit.

Zhe He, Yide Zhang, Xin Tong, Lei Li, Lihong V Wang

Open access · goldAbstract read
In one paragraph

Article in Nature communications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
8.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 60 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Application of quantum imaging in biology.Biomedical optics express · 2025
    Review
  8. Review
  9. Entanglement-controlled vectorial meta-holography.Light, science & applications · 2025
    Article
  10. Article
  11. Quantum Plexcitonic Sensing.Nano letters · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Zhe He *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 E. California Blvd., MC 138-78, Pasadena, CA 91125, USA.
Yide Zhang *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 E. California Blvd., MC 138-78, Pasadena, CA 91125, USA.ORCID http://orcid.org/0000-0002-9463-3970
Xin Tong *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 E. California Blvd., MC 138-78, Pasadena, CA 91125, USA.
Lei LiCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 E. California Blvd., MC 138-78, Pasadena, CA 91125, USA.
Lihong V WangCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 E. California Blvd., MC 138-78, Pasadena, CA 91125, USA. LVW@caltech.edu.ORCID http://orcid.org/0000-0001-9783-4383
California Institute of Technology · US

Funding

The Center for Label-free Imagingand Multiscale Biophotonics (CLIMB)P41EB031772 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI Stephen A Boppart · 2022 to 2026
$7.6M
High-speed panoramic 3D photoacoustic computed tomography of the breastR35CA220436 · NCI · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI WANG, LIHONG · 2018 to 2024
$6.4M
Label-free intraoperative photoacoustic microscopy for rapid diagnosis of tissue biopsies with specimen integrityR01EB028277 · NIBIB · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI D'APUZZO, MASSIMO, WANG, LIHONG · 2019 to 2022
$2.6M
NCI NIH HHS R35 CA220436NIBIB NIH HHS P41 EB031772NIBIB NIH HHS R01 EB028277
6 · The paper itself

Abstract

Entangled biphoton sources exhibit nonclassical characteristics and have been applied to imaging techniques such as ghost imaging, quantum holography, and quantum optical coherence tomography. The development of wide-field quantum imaging to date has been hindered by low spatial resolutions, speeds, and contrast-to-noise ratios (CNRs). Here, we present quantum microscopy by coincidence (QMC) with balanced pathlengths, which enables super-resolution imaging at the Heisenberg limit with substantially higher speeds and CNRs than existing wide-field quantum imaging methods. QMC benefits from a configuration with balanced pathlengths, where a pair of entangled photons traversing symmetric paths with balanced optical pathlengths in two arms behave like a single photon with half the wavelength, leading to a two-fold resolution improvement. Concurrently, QMC resists stray light up to 155 times stronger than classical signals. The low intensity and entanglement features of biphotons in QMC promise nondestructive bioimaging. QMC advances quantum imaging to the microscopic level with significant improvements in speed and CNR toward the bioimaging of cancer cells. We experimentally and theoretically prove that the configuration with balanced pathlengths illuminates an avenue for quantum-enhanced coincidence imaging at the Heisenberg limit.

Identifiers

PMID37117176
PMCPMC10147633
OpenAlexW4367316288

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.