ArticleHerzschrittmachertherapie & Elektrophysiologie2023
[Pacemaker infection in fragile patients].
Article in Herzschrittmachertherapie & Elektrophysiologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- Delphi consensus recommendations for preventing and treating cardiac implantable electronic device infections beyond current guidelines.Scientific reports · 2026Article
- Antimicrobial Efficacy of a Taurolidine-Based Antimicrobial Compound on Contaminated Surfaces Simulated in a Standardized 4-Field Test.Advanced healthcare materials · 2026Article
- An unusual cause of inappropriate shocks delivered by an implantable cardioverter defibrillator.BMC cardiovascular disorders · 2024Article
- Factors of mortality in patients with cardiac implantable electronic device: 5-year experience.Revista da Associacao Medica Brasileira (1992) · 2024Article
- The European TauroPace™ Registry.Methods and protocols · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Complications associated with cardiac implantable electric devices (CIED) are manifold. They include lead dislocation, twiddler's syndrome, device malfunction, haematoma formation and infection. Infections can be divided into acute, subacute and late infections. Both the time of onset and the route of infection play a crucial role. The consequences of a CIED infection are devastating. The most modern treatment methods include the removal of all implanted implants. If complete removal is not followed in the event of infection, there is a high rate of infection recurrence. Open thoracic surgery to remove infected CIED hardware has been replaced by percutaneous lead extraction procedures. Lead extraction requires specialised equipment and expertise and may not be readily available or feasible for some patients. Each extraction procedure is associated with a small risk of potentially fatal complications (e.g. cardiac avulsion, vascular avulsion, haemothorax and cardiac tamponade). For these reasons, the performance of such procedures should be limited to centres with adequate equipment and experience. Successful salvage of CIED systems with in situ sterilisation of contaminated hardware has been reported. In our case, we report the successful salvage of an exposed generator in a frail patient treated more than 5 years after the last generator replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.