Evidence map›Paper›PMID 37113098›Full record

ArticleSkin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)2023

Spectral analysis of laser speckle contrast imaging and infrared thermography to assess skin microvascular reactive hyperemia.

Yuanliang Tang, Fei Xu, Peng Lei, Guixiang Li, Zhongwei Tan

Open access · hybridAbstract read
In one paragraph

Article in Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Quantitative interpretation of infrared images of lower limbs in individuals with and without type 2 diabetes mellitus.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2024
    Article
  4. Spectral analysis of laser speckle contrast imaging and infrared thermography to assess skin microvascular reactive hyperemia.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Yuanliang TangInstitute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou, China.ORCID https://orcid.org/0000-0002-2670-7747
Fei XuInstitute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou, China.
Peng LeiInstitute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou, China.
Guixiang LiInstitute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou, China.
Zhongwei TanInstitute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou, China.
Guangdong Academy of Sciences · CN

Funding

the Fund Projects of Guangdong Academy of Sciences 2020GDASYL-20200103037the Fund Projects of Guangdong Academy of Sciences 2020GDASYL-20200402002the Fund Projects of Guangdong Academy of Sciences 2021GDASYL-20210103028the Fund Projects of Guangdong Academy of Sciences 2021GDASYL-20210103031the Fund Projects of Guangdong Academy of Sciences 2022GDASZH-2022010110the Natural Science Foundation of Guangdong Province 2020A1515010954
6 · The paper itself

Abstract

backgroundPost-occlusive reactive hyperemia (PORH) test with signal spectral analysis coupled provides potential indicators for the assessment of microvascular functions.

objectiveThe objective of this study is to investigate the variations of skin blood flow and temperature spectra in the PORH test. Furthermore, to quantify the oscillation amplitude response to occlusion within different frequency ranges. MATERIALS AND

methodsTen healthy volunteers participated in the PORH test and their hand skin temperature and blood flow images were captured by infrared thermography (IRT) and laser speckle contrast imaging (LSCI) system, respectively. Extracted signals from selected areas were then transformed into the time-frequency space by continuous wavelet transform for cross-correlation analysis and oscillation amplitude response comparisons.

resultsThe LSCI and IRT signals extracted from fingertips showed stronger hyperemia response and larger oscillation amplitude compared with other areas, and their spectral cross-correlations decreased with frequency. According to statistical analysis, their oscillation amplitudes in the PORH stage were obviously larger than the baseline stage within endothelial, neurogenic, and myogenic frequency ranges (p < 0.05), and their quantitative indicators of oscillation amplitude response had high linear correlations within endothelial and neurogenic frequency ranges.

conclusionComparisons of IRT and LSCI techniques in recording the reaction to the PORH test were made in both temporal and spectral domains. The larger oscillation amplitudes suggested enhanced endothelial, neurogenic, and myogenic activities in the PORH test. We hope this study is also significant for investigations of response to the PORH test by other non-invasive techniques.

Indexed as

HyperemiaHumansLaser-Doppler FlowmetryLaser Speckle Contrast ImagingMicrocirculationRegional Blood FlowSkinThermographyendothelial regulationflowmotionpost-occlusive reactive hyperemiavasomotionwavelet analysis

Identifiers

PMID37113098
PMCPMC10234160
OpenAlexW4365148189

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.