Evidence map›Paper›PMID 37112386›Full record

ArticleSensors (Basel, Switzerland)2023

Automation and Optimization of Rat Heart Decellularization Using a Vibrating Fluid Column.

Dumitru-Daniel Bonciog, Mihaela-Ruxandra Lascu, Liliana Mâțiu-Iovan, Valentin Laurențiu Ordodi

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Dumitru-Daniel BonciogMeasurements and Optical Electronics Department, Politehnica University Timisoara, 300006 Timisoara, Romania.
Mihaela-Ruxandra LascuMeasurements and Optical Electronics Department, Politehnica University Timisoara, 300006 Timisoara, Romania.
Liliana Mâțiu-IovanMeasurements and Optical Electronics Department, Politehnica University Timisoara, 300006 Timisoara, Romania.ORCID 0000-0001-5261-4897
Valentin Laurențiu OrdodiChemistry and Engineering of Organic and Natural Compounds Department, University Politehnica Timisoara, 300006 Timisoara, Romania.
Polytechnic University of Timişoara · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents the validation of a software application to optimize the discoloration process in simulated hearts and to automate and determine the final moment of decellularization in rat hearts using a vibrating fluid column. The implemented algorithm specifically for the automated verification of a simulated heart's discoloration process was optimized in this study. Initially, we used a latex balloon containing enough dye to reach the opacity of a heart. The complete discoloration process corresponds to complete decellularization. The developed software automatically detects the complete discoloration of a simulated heart. Finally, the process stops automatically. Another goal was to optimize the Langendorff-type experimental apparatus, which is pressure-controlled and equipped with a vibrating fluid column that shortens the decellularization time by mechanically acting directly on cell membranes. Control experiments were performed with the designed experimental device and the vibrating liquid column using different decellularization protocols for hearts taken from rats. In this work, we used a commonly utilized solution based on sodium dodecyl sulfate. Ultraviolet spectrophotometry was used to measure the evolution of the dye concentration in the simulated hearts and, similarly, to determine the concentrations of deoxyribonucleic acid (DNA) and proteins in the rat hearts.

Indexed as

Tissue EngineeringTissue ScaffoldsAnimalsAutomationCell MembraneHeartRatsbiomedical imagescardiac biomatrixheart decellularizationheart discolorationheart simulationLangendorff devicesoftware applicationsoftware optimizationtissue engineeringvibrating fluid column

Identifiers

PMID37112386
PMCPMC10140852
OpenAlexW4366088559

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.