Evidence map›Paper›PMID 37112335›Full record

ArticleSensors (Basel, Switzerland)2023

An Improvement Strategy for Indoor Air Quality Monitoring Systems.

Claudio De Capua, Gaetano Fulco, Mariacarla Lugarà, Filippo Ruffa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Air pollution and alveolar health.European respiratory review : an official journal of the European Respiratory Society · 2025
    Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Claudio De CapuaDIIES-Department of Information Engineering, Infrastructure and Sustainable Energy, Mediterranea University of Reggio Calabria, 89122 Reggio Calabria, Italy.ORCID 0000-0002-4322-4923
Gaetano FulcoDIIES-Department of Information Engineering, Infrastructure and Sustainable Energy, Mediterranea University of Reggio Calabria, 89122 Reggio Calabria, Italy.ORCID 0000-0003-1192-6784
Mariacarla LugaràDIIES-Department of Information Engineering, Infrastructure and Sustainable Energy, Mediterranea University of Reggio Calabria, 89122 Reggio Calabria, Italy.ORCID 0000-0003-1845-2112
Filippo RuffaDIIES-Department of Information Engineering, Infrastructure and Sustainable Energy, Mediterranea University of Reggio Calabria, 89122 Reggio Calabria, Italy.ORCID 0000-0001-5863-1065

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Air quality has a huge impact on the comfort and healthiness of various environments. According to the World Health Organization, people who are exposed to chemical, biological and/or physical agents in buildings with low air quality and poor ventilation are more prone to be affected by psycho-physical discomfort, respiratory tract and central nervous system diseases. Moreover, in recent years, the time spent indoors has increased by around 90%. If we consider that respiratory diseases are mainly transmitted from human to human through close contact, airborne respiratory droplets and contaminated surfaces, and that there is a strict relationship between air pollution and the spread of the diseases, it becomes even more necessary to monitor and control these environmental conditions. This situation has inevitably led us to consider renovating buildings with the aim of improving both the well-being of the occupants (safety, ventilation, heating) and the energy efficiency, including monitoring the internal comfort using sensors and the IoT. These two objectives often require opposite approaches and strategies. This paper aims to investigate indoor monitoring systems to increase the quality of life of occupants, proposing an innovative approach consisting of the definition of new indices that consider both the concentration of the pollutants and the exposure time. Furthermore, the reliability of the proposed method was enforced using proper decision-making algorithms, which allows one to consider measurement uncertainty during decisions. Such an approach allows for greater control over the potentially harmful conditions and to find a good trade-off between well-being and the energy efficiency objectives.

Indexed as

Air PollutantsAir PollutionAir Pollution, IndoorEnvironmental MonitoringHumansQuality of LifeReproducibility of ResultsAir Pollutantsair qualitydecision makingIAQIoTmonitoring systemssensing