Evidence map›Paper›PMID 37112071›Full record

ArticlePolymers2023

Influence of Different Hot Runner-Systems in the Injection Molding Process on the Structural and Mechanical Properties of Regenerated Cellulose Fiber Reinforced Polypropylene.

Jan-Christoph Zarges, André Schlink, Fabian Lins, Jörg Essinger, Stefan Sommer, Hans-Peter Heim

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jan-Christoph ZargesInstitute of Material Engineering, Polymer Engineering, University of Kassel, 34125 Kassel, Germany.ORCID 0000-0003-0617-0257
André SchlinkInstitute of Material Engineering, Polymer Engineering, University of Kassel, 34125 Kassel, Germany.ORCID 0000-0002-3874-2021
Fabian LinsInstitute of Material Engineering, Polymer Engineering, University of Kassel, 34125 Kassel, Germany.ORCID 0009-0009-6827-8889
Jörg EssingerGünther Heisskanaltechnik GmbH, 35066 Frankenberg (Eder), Germany.
Stefan SommerGünther Heisskanaltechnik GmbH, 35066 Frankenberg (Eder), Germany.
Hans-Peter HeimInstitute of Material Engineering, Polymer Engineering, University of Kassel, 34125 Kassel, Germany.
University of Kassel · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The increasing demand for renewable raw materials and lightweight composites leads to an increasing request for natural fiber composites (NFC) in series production. In order to be able to use NFC competitively, they must also be processable with hot runner systems in injection molding series production. For this reason, the influences of two hot runner systems on the structural and mechanical properties of Polypropylene with 20 wt.% regenerated cellulose fibers (RCF) were investigated. Therefore, the material was processed into test specimens using two different hot runner systems (open and valve gate) and six different process settings. The tensile tests carried out showed very good strength for both hot runner systems, which were max. 20% below the reference specimen processed with a cold runner and, however, significantly influenced by the different parameter settings. Fiber length measurements with the dynamic image analysis showed approx. 20% lower median values of GF and 5% lower of RCF through the processing with both hot runner systems compared to the reference, although the influence of the parameter settings was small. The X-ray microtomography performed on the open hot runner samples showed the influences of the parameter settings on the fiber orientation. In summary, it was shown that RCF composites can be processed with different hot runner systems in a wide process window. Nevertheless, the specimens of the setting with the lowest applied thermal load showed the best mechanical properties for both hot runner systems. It was furthermore shown that the resulting mechanical properties of the composites are not only due to one structural property (fiber length, orientation, or thermally induced changes in fiber properties) but are based on a combination of several material- and process-related properties.

Indexed as

dynamic image analysisfiber lengthfiber orientationhot runner systeminjection moldingmechanical propertiesnatural fiber compositesviscose fiberX-ray microtomography analysis

Identifiers

PMID37112071
PMCPMC10143953
OpenAlexW4366281341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.