Evidence map›Paper›PMID 37109987›Full record

ArticleMaterials (Basel, Switzerland)2023

Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce.

Zhongmin Xiao, Longfei Wu, Wenqiang Wu, Ruizhi Tang, Jietao Dai, Dachang Zhu

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Zhongmin XiaoSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Longfei WuSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Wenqiang WuSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Ruizhi TangSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Jietao DaiSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
Dachang ZhuSchool of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.ORCID 0000-0002-0691-7755
Guangzhou University · CN

Funding

Guangzhou City School Joint Project SL2023A03J00681
6 · The paper itself

Abstract

Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is -1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.

Indexed as

femoral stemfinite element analysismulti-scale conditionsstress shieldingtopology optimization

Identifiers

PMID37109987
PMCPMC10143993
OpenAlexW4366091593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked