ArticleMaterials (Basel, Switzerland)2023
Investigation of MAF for Finishing the Inner Wall of Super-Slim Cardiovascular Stents Tube.
Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Optimization of Magnetic Abrasive Finishing Parameters for Co-Cr Alloy Vascular Stent Tubing Using PSO-SVM.Micromachines · 2026Article
- Investigation of Synthesis, Characterization, and Finishing Applications of Spherical AlMicromachines · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The internal wall of cardiovascular stent tubing produced by a drawing process has defects such as pits and bumps, making the surface rough and unusable. In this research, the challenge of finishing the inner wall of a super-slim cardiovascular stent tube was solved by magnetic abrasive finishing. Firstly, a spherical CBN magnetic abrasive was prepared by a new method, plasma molten metal powders bonding with hard abrasives; then, a magnetic abrasive finishing device was developed to remove the defect layer from the inner wall of ultrafine long cardiovascular stent tubing; finally, response surface tests were performed and parameters were optimized. The results show that the prepared spherical CBN magnetic abrasive has a perfect spherical appearance; the sharp cutting edges cover the surface layer of the iron matrix; the developed magnetic abrasive finishing device for a ultrafine long cardiovascular stent tube meets the processing requirements; the process parameters are optimized by the established regression model; and the inner wall roughness (Ra) of the nickel-titanium alloy cardiovascular stents tube is reduced from 0.356 μm to 0.083 μm, with an error of 4.3% from the predicted value. Magnetic abrasive finishing effectively removed the inner wall defect layer and reduced the roughness, and this solution provides a reference for polishing the inner wall of ultrafine long tubes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials