Evidence map›Paper›PMID 37106603›Full record

ArticleBioengineering (Basel, Switzerland)2023

Experimental Demonstration of Compact Polymer Mass Transfer Device Manufactured by Additive Manufacturing with Hydrogel Integration to Bio-Mimic the Liver Functions.

Ganesan Narendran, Avdhoot Walunj, A Mohan Kumar, Praveen Jeyachandran, Nasser S Awwad, Hala A Ibrahium, M R Gorji, D Arumuga Perumal

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ganesan NarendranMicro and Nanofluidics Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Suruthkal, Mangaluru 575025, India.
Avdhoot WalunjDepartment of Mechanical Engineering, Mahatma Phule Krishi Vidyapeeth, Rahuri 413722, Maharashtra, India.ORCID 0000-0002-3163-1548
A Mohan KumarDepartment of Clinical Microbiology, All India Institute of Medical Sciences, Mangalagiri 522503, Andhra Pradesh, India.
Praveen JeyachandranDepartment of Mechanical Engineering, National Institute of Technology Karnataka, Suruthkal, Mangaluru 575025, India.
Nasser S AwwadDepartment of Chemistry, College of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia.ORCID 0000-0002-3477-6996
Hala A IbrahiumDepartment of Biology, College of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia.
M R GorjiFaculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium.
D Arumuga PerumalMicro and Nanofluidics Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Suruthkal, Mangaluru 575025, India.ORCID 0000-0001-5797-2925

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, we designed and demonstrated a stimuli-responsive hydrogel that mimics the mass diffusion function of the liver. We have controlled the release mechanism using temperature and pH variations. Additive manufacturing technology was used to fabricate the device with nylon (PA-12), using selective laser sintering (SLS). The device has two compartment sections: the lower section handles the thermal management, and feeds temperature-regulated water into the mass transfer section of the upper compartment. The upper chamber has a two-layered serpentine concentric tube; the inner tube carries the temperature-regulated water to the hydrogel using the given pores. Here, the hydrogel is present in order to facilitate the release of the loaded methylene blue (MB) into the fluid. By adjusting the fluid's pH, flow rate, and temperature, the deswelling properties of the hydrogel were examined. The weight of the hydrogel was maximum at 10 mL/min and decreased by 25.29% to 10.12 g for the flow rate of 50 mL/min. The cumulative MB release at 30 °C increased to 47% for the lower flow rate of 10 mL/min, and the cumulative release at 40 °C climbed to 55%, which is 44.7% more than at 30 °C. The MB release rates considerably increased when the pH dropped from 12 to 8, showing that the lower pH had a major impact on the release of MB from the hydrogel. Only 19% of the MB was released at pH 12 after 50 min, and after that, the release rate remained nearly constant. At higher fluid temperatures, the hydrogels lost approximately 80% of their water in just 20 min, compared to a loss of 50% of their water at room temperature. The outcomes of this study may contribute to further developments in artificial organ design.

Indexed as

additive manufacturingbiomimicryhydrogelliver functionselective laser sintering

Identifiers

PMID37106603
PMCPMC10135587

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.