Evidence map›Paper›PMID 37106587›Full record

ArticleBioengineering (Basel, Switzerland)2023

Cuff-Less Blood Pressure Prediction Based on Photoplethysmography and Modified ResNet.

Caijie Qin, Yong Li, Chibiao Liu, Xibo Ma

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Caijie QinInstitute of Information Engineering, Sanming University, Sanming 365004, China.
Yong LiInstitute of Information Engineering, Sanming University, Sanming 365004, China.
Chibiao LiuInstitute of Information Engineering, Sanming University, Sanming 365004, China.
Xibo MaCBSR&NLPR, Institute of Automation, Chinese Academy of Sciences, Beijing 100049, China.

Funding

National Natural Science Foundation of China #82090051,#81871442,Natural Science Foundation of Fujian Province 2022J01132291young and 430 middle-aged teachers education research project of Fujian Province JAT210422)Youth Innovation Promotion Association CAS #Y201930)
6 · The paper itself

Abstract

Cardiovascular disease (CVD) has become a common health problem of mankind, and the prevalence and mortality of CVD are rising on a year-to-year basis. Blood pressure (BP) is an important physiological parameter of the human body and also an important physiological indicator for the prevention and treatment of CVD. Existing intermittent measurement methods do not fully indicate the real BP status of the human body and cannot get rid of the restraining feeling of a cuff. Accordingly, this study proposed a deep learning network based on the ResNet34 framework for continuous prediction of BP using only the promising PPG signal. The high-quality PPG signals were first passed through a multi-scale feature extraction module after a series of pre-processing to expand the perceptive field and enhance the perception ability on features. Subsequently, useful feature information was then extracted by stacking multiple residual modules with channel attention to increase the accuracy of the model. Lastly, in the training stage, the Huber loss function was adopted to stabilize the iterative process and obtain the optimal solution of the model. On a subset of the MIMIC dataset, the errors of both SBP and DBP predicted by the model met the AAMI standards, while the accuracy of DBP reached Grade A of the BHS standard, and the accuracy of SBP almost reached Grade A of the BHS standard. The proposed method verifies the potential and feasibility of PPG signals combined with deep neural networks in the field of continuous BP monitoring. Furthermore, the method is easy to deploy in portable devices, and it is more consistent with the future trend of wearable blood-pressure-monitoring devices (e.g., smartphones and smartwatches).

Indexed as

blood pressurechannel attentioncontinuous predictionmulti-scale feature extractionResNet34

Identifiers

PMID37106587
PMCPMC10135940

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.