Evidence map›Paper›PMID 37106586›Full record

ArticleBioengineering (Basel, Switzerland)2023

Woven Vascular Stent-Grafts with Surface Modification of Silk Fibroin-Based Paclitaxel/Metformin Microspheres.

Mengdi Liang, Fang Li, Yongfeng Wang, Hao Chen, Jingjing Tian, Zeyu Zhao, Karl H Schneider, Gang Li

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Transport across the thoracic aortic wall: implications for aneurysm pathobiology, diagnosis, and treatment.American journal of physiology. Heart and circulatory physiology · 2025
    Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Mengdi LiangNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
Fang LiNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
Yongfeng WangNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
Hao ChenNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
Jingjing TianNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
Zeyu ZhaoDepartment of Applied Physics, The Hong Kong Polytechnic University, 11 Yukchoi Rd, Hung Hom, Kowloon, Hong Kong 999077, China.
Karl H SchneiderCenter for Biomedical Research and Translational Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0003-4605-4795
Gang LiNational Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.ORCID 0000-0002-8080-4134
Soochow University · CNHong Kong Polytechnic University · HKMedical University of Vienna · AT

Funding

China National Textile and Apparel Council J202002Jiangsu Advanced Textile Engineering Technology Center XJFZ/2021/7Jiangsu Provincial Department of Science and Technology BZ2022017Ministry of Science and Technology KY202201002National Key R&D Program of China 2021YFE0111100
6 · The paper itself

Abstract

In-stent restenosis caused by tumor ingrowth increases the risk of secondary surgery for patients with abdominal aortic aneurysms (AAA) because conventional vascular stent grafts suffer from mechanical fatigue, thrombosis, and endothelial hyperplasia. For that, we report a woven vascular stent-graft with robust mechanical properties, biocompatibility, and drug delivery functions to inhibit thrombosis and the growth of AAA. Paclitaxel (PTX)/metformin (MET)-loaded silk fibroin (SF) microspheres were self-assembly synthesized by emulsification-precipitation technology and layer-by-layer coated on the surface of a woven stent via electrostatic bonding. The woven vascular stent-graft before and after coating drug-loaded membranes were characterized and analyzed systematically. The results show that small-sized drug-loaded microspheres increased the specific surface area and promoted the dissolution/release of drugs. The stent-grafts with drug-loaded membranes exhibited a slow drug-release profile more for than 70 h and low water permeability at 158.33 ± 17.56 mL/cm

Indexed as

drug releasemetforminpaclitaxelsilk fibroinstent-graft

Identifiers

PMID37106586
PMCPMC10136065
OpenAlexW4360855001

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked