Evidence map›Paper›PMID 37102600›Full record

Trial reportJournal of diabetes science and technology2024

Noninvasive Continuous Glucose Monitoring With a Novel Wearable Dial Resonating Sensor: A Clinical Proof-of-Concept Study.

Consuelo Handy, Mohamed Sabih Chaudhry, Muhammad Rafaqat Ali Qureshi, Bradley Love, John Shillingford, Leona Plum-Mörschel, Eric Zijlstra

Registry-linked trialAbstract readClinical Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05023798 (Development Study to Undertake a Comprehensive Performance Evaluation of Prototype Non-Invasive Blood Glucose Measurement Systems Compared to a Standard), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05023798 unknown statusnot on this map

Development Study to Undertake a Comprehensive Performance Evaluation of Prototype Non-Invasive Blood Glucose Measurement Systems Compared to a Standard (Invasive) Measurement Method of Blood Glucose

TypeobservationalSponsorAfon TechnologyRan2021 to 2022Enrolled50ConditionsDiabetes Mellitus, Type 2, Diabetes Mellitus, Type 1ArmsATD (device test)
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Consuelo HandyAfon Technology Ltd, Caldicot, UK.ORCID 0000-0001-8888-8945
Mohamed Sabih ChaudhryAfon Technology Ltd, Caldicot, UK.ORCID 0000-0002-2568-8396
Muhammad Rafaqat Ali QureshiAfon Technology Ltd, Caldicot, UK.ORCID 0000-0002-2971-6235
Bradley LoveCitalytics, Towson, MD, USA.ORCID 0000-0001-7528-3867
John ShillingfordAfon Technology Ltd, Caldicot, UK.ORCID 0000-0002-0019-5739
Leona Plum-MörschelProfil, Neuss, Germany.ORCID 0000-0002-1907-761X
Eric ZijlstraProfil, Neuss, Germany.ORCID 0000-0001-8843-5452

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA noninvasive, wearable continuous glucose monitor would be a major advancement in diabetes therapy. This trial investigated a novel noninvasive glucose monitor which analyzes spectral variations in radio frequency/microwave signals reflected from the wrist.

methodsA single-arm, open-label, experimental study compared glucose values from a prototype investigational device with laboratory glucose measurements from venous blood samples (Super GL Glucose Analyzer, Dr. Müller Gerätebau GmbH) at varying levels of glycemia. The study included 29 male participants with type 1 diabetes (age range = 19-56 years). The study comprised three stages with the following aims: (1) demonstrate initial proof-of-principle, (2) test an improved device design, and (3) test performance on two consecutive days without device recalibration. The co-primary endpoints in all trial stages were median and mean absolute relative difference (ARD) calculated across all data points.

resultsIn stage 1, the median and mean ARDs were 30% and 46%, respectively. Stage 2 produced marked performance improvements with a median and mean ARD of 22% and 28%, respectively. Stage 3 showed that, without recalibration, the device performed as well as the initial prototype (stage 1) with a median and mean ARD of 35% and 44%, respectively.

conclusionThis proof-of-concept study shows that a novel noninvasive continuous glucose monitor was capable of detecting glucose levels. Furthermore, the ARD results are comparable to first models of commercially available minimally invasive products without the need to insert a needle. The prototype has been further developed and is being tested in subsequent studies. TRIAL REGISTRATION NUMBER: NCT05023798.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Proof of Concept StudyWearable Electronic DevicesAdultContinuous Glucose MonitoringEquipment DesignHumansMaleMiddle AgedYoung AdultBlood Glucoseblood glucose self-monitoringdiabetes mellitusmicrowavesnoninvasiveradio frequencywearable electronic devices

Identifiers

PMID37102600
PMCPMC11529082

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.