Evidence map›Paper›PMID 37101942›Full record

ArticleBuilding simulation2023

A cost-effectiveness assessment of the operational parameters of central HVAC systems during pandemics.

Yufan Chang, Zhengtao Ai, Jinjun Ye, Guochuan Ma

Abstract read
In one paragraph

Article in Building simulation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Managing infectious aerosols to counter engineered pandemics: Current recommendations and future research.Risk analysis : an official publication of the Society for Risk Analysis · 2025
    Guideline
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yufan ChangDepartment of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China.
Zhengtao AiDepartment of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China.
Jinjun YeDepartment of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China.
Guochuan MaChina Southwest Architectural Design and Research Institute, Chengdu, Sichuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study develops a cost-effectiveness assessment model to analyze the performance of major operational parameters of central HVAC systems in terms of airborne transmission risk, energy consumption, and medical and social cost. A typical multi-zone building model with a central HVAC system is built numerically, and the effect of outdoor air (OA) ratio (from 30% to 100%) and filtration level (MERV 13, MERV 16, and HEPA) are assessed under the conditions of five climate zones in China. Compared with the baseline case with 30% OA and MERV 13 filtration, the airborne transmission risk in zones without infector is negligibly reduced with the increase in OA ratio and the upgrade of filtration level, owing to their slight modification on the equivalent ventilation rate of virus-free air. However, depending on climate zone, a 10% increase in OA ratio results in 12.5%-78.6% and 0.1%-8.6% increase in heating and cooling energy consumption, respectively, while an upgrade of filtration level to MERV 16 and HEPA results in an increase of 0.08%-0.2% and 1.4%-2.6%, respectively. Overall, when compared to the use of 100% OA ratio and HEPA filtration, the application of 30% or 40% OA ratio and MERV 13 filtration would save annually an energy and facility related cost of $29.4 billion in China, though giving an increase of approximately $0.1 billion on medical and social cost from the increased number of confirmed cases. This study provides basic method and information for the formulation of cost-effective operational strategies of HVAC systems coping with the airborne transmission, especially in resource-limited regions.

Indexed as

airborne transmission riskcost-effectivenessenergy consumptionfiltration leveloutdoor air ratio

Identifiers

PMID37101942
PMCPMC10040913

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked