ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026
The "pipe-anchor" technique: A method for intra-aneurysmal loop reduction using a partially unsheathed pipeline stent.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
PurposeLarge aneurysms often present a challenge for endovascular navigation, as they may require utilization of "around-the-world" technique for distal access. In this study, we describe the use of a pipeline stent to stabilize the microcatheter allowing gradual unsheathing and straightening of the microcatheter within the aneurysm enabling stent deployment.MethodsA pipeline stent is partially deployed distal to the aneurysm, after using intra-aneurysmal loop ("around-the-world") to cross the aneurysm. Partially unsheathed, using its radial force and vessel wall friction to establish an anchoring point, the microcatheter is stabilized and pulled with the stent locked to gradually to allow loop reduction and microsystem straightening, allowing unsheathing as the microsystem is aligned with the inflow and outflow vessel.ResultsTwo patients harboring cavernous segment aneurysms (measuring 18 × 12 mm and 21 × 24 mm) were treated by 3.75 × 25 mm and 4.25 × 25 mm pipeline devices, respectively, using this technique, deployed through a Phenom 0.027" microcatheter. Patients did well clinically with no thromboembolic complications, as follow-up imaging demonstrated good wall apposition and appreciable contrast stagnation.ConclusionAnchoring for loop reduction was previously described using a non-flow diverter stents or balloon requiring additional devices and exchange maneuvers to deploy a pipeline. The "pipe anchor" technique describes the use of a partially deployed flow diverter system as an anchor. This report suggests that pipeline radial force, albeit low, is sufficient. We believe that this method is worthy of consideration in select cases as a first choice and can be valuable tool in the armamentarium of the endovascular neurosurgeon.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.