Evidence map›Paper›PMID 37097820›Full record

ArticleApplied spectroscopy2023

10 kHz Shifted-Excitation Raman Difference Spectroscopy with Charge-Shifting Charge-Coupled Device Read-Out for Effective Mitigation of Dynamic Interfering Backgrounds.

Sara Mosca, Kay Sowoidnich, Megha Mehta, William H Skinner, Benjamin Gardner, Francesca Palombo, Nicholas Stone, Pavel Matousek

Open access · hybridAbstract read
In one paragraph

Article in Applied spectroscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Sara MoscaCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus OX11 0QX, UK.ORCID 0000-0001-9479-5614
Kay SowoidnichFerdinand-Braun-Institut, Leibniz-Institut für Höchstfrequenztechnik, Gustav-Kirchhoff-Str. 4, 12489 Berlin, Germany.ORCID 0000-0002-7173-2677
Megha MehtaDepartment of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK.
William H SkinnerDepartment of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK.ORCID 0000-0002-4307-8356
Benjamin GardnerDepartment of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK.
Francesca PalomboDepartment of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK.ORCID 0000-0001-6355-2601
Nicholas StoneDepartment of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, UK.
Pavel MatousekCentral Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRI, Harwell Campus OX11 0QX, UK.ORCID 0000-0003-0912-5339
University of Exeter · GBRutherford Appleton Laboratory · GBFerdinand-Braun-Institut · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work we demonstrate an advanced concept of a charge-shifting charge-coupled device (CCD) read-out combined with shifted excitation Raman difference spectroscopy (SERDS) capable of operating at up to 10 kHz acquisition rates for the effective mitigation of fast-evolving interfering backgrounds in Raman spectroscopy. This rate is 10-fold faster than that achievable with an instrument we described previously and is overall 1000-fold faster than possible with conventional spectroscopic CCDs capable of operating at up to ∼10 Hz rates. The speed enhancement was realized by incorporating a periodic mask at the internal slit of an imaging spectrometer permitting a smaller shift of the charge on the CCD (8 pixels) to be required during the cyclic shifting process compared with the earlier design which employed an 80-pixel shift. The higher acquisition speed enables the more accurate sampling of the two SERDS spectral channels, enabling it to effectively tackle highly challenging situations with rapidly evolving interfering fluorescence backgrounds. The performance of the instrument is evaluated for heterogeneous fluorescent samples which are moved rapidly in front of the detection system aiming at the differentiation of chemical species and their quantification. The performance of the system is compared with that of the earlier 1 kHz design and a conventional CCD operated at its maximum rate of 5.4 Hz as previously. In all situations tested, the newly developed 10 kHz system outperformed the earlier variants. The 10 kHz instrument can benefit a number of prospective applications including: disease diagnosis where high sensitivity mapping of complex biological matrices in the presence of natural fluorescence bleaching restricts achievable limits of detection; accurate data acquisition from moving heterogeneous samples (or moving a handheld instrument in front of the sample during data acquisition) or data acquisition under varying ambient light conditions (e.g., due to casting shadows, sample or instrument movement). Other beneficial scenarios include monitoring rapidly evolving Raman signals in the presence of largely static background signals such as in situations where a heterogeneous sample is moving rapidly in front of a detection system (e.g., a conveyor belt) in the presence of static ambient light.

Indexed as

Spectrum Analysis, RamanSpectrometry, Fluorescenceambient light interferenceCCDcharge-coupled devicecharge-shiftingfluorescence interferenceRaman spectroscopySERDSshifted excitation Raman difference spectroscopy

Identifiers

PMID37097820
PMCPMC10331517
OpenAlexW4366982377

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.