Coronary Perfusion After Valve-in-Valve Transcatheter Aortic Valve Implantation in Small Aortic Root: In Vitro Experimental Assessment.

Michal Jaworek, Guido Gelpi, Francesca Perico, Claudia Romagnoni, Giordano Tasca, Eleonora Salurso, Monica Contino, Alberto Redaelli, Gianfranco Beniamino Fiore, Riccardo Vismara

Open access · hybridAbstract read
In one paragraph

Article in Journal of cardiovascular translational research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Michal JaworekDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy.ORCID http://orcid.org/0000-0002-1484-8913
Guido GelpiCardiac Surgery Unit, Fondazione IRCCS Ca' Grande Ospedale Maggiore Policlinico, Milan, Italy.
Francesca PericoDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy.
Claudia RomagnoniCardiac Surgery Unit, Fondazione IRCCS Ca' Grande Ospedale Maggiore Policlinico, Milan, Italy.
Giordano TascaCardiac Surgery Department, Heart Health Center, King Saud Medical City, Riyadh, Kingdom of Saudi Arabia.
Eleonora SalursoDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy.
Monica ContinoForcardioLab-Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy.
Alberto RedaelliDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy.
Gianfranco Beniamino FioreDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy.
Riccardo VismaraDepartment of Electronics, Information and Bioengineering, Politecnico Di Milano, Via Golgi 39, 20133, Milan, Italy. riccardo.vismara@polimi.it.
Fondazione Europea Ricerca Biomedica · ITFondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico · ITKing Saud Medical City · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to quantify the coronary perfusion after VIV-TAVI in a high-risk aortic root anatomy. 3D printed models of small aortic root were used to simulate the implantation of a TAVI prosthesis (Portico 23) into surgical prostheses (Trifecta 19 and 21). The aortic root models were tested in a pulsatile in vitro bench setup with a coronary perfusion simulator. The tests were performed at baseline and post-VIV-TAVI procedure in aligned and misaligned commissural configurations under simulated hemodynamic rest and exercise conditions. The experimental design provided highly controllable and repeatable flow and pressure conditions. The left and right coronary mean flow did not differ significantly at pre- and post-VIV-TAVI procedure in any tested configurations. The commissural misalignment did not induce any significant alterations to the coronary flow. High-risk aortic root anatomy did not trigger coronary ostia obstruction or coronary flow alteration after transcatheter aortic valve implantation in a surgical bioprosthesis as shown from in-vitro flow loop tests.

Indexed as

Aortic Valve StenosisBioprosthesisCoronary OcclusionHeart Valve ProsthesisHeart Valve Prosthesis ImplantationTranscatheter Aortic Valve ReplacementAorta, ThoracicAortic ValveHumansPerfusionProsthesis DesignProsthesis FailureTreatment OutcomeAortic rootAortic valveBenchCoronary flowCoronary obstructionIn vitroTAVITAVRValve-in-valve

Identifiers

PMID37097591
PMCPMC10480284
OpenAlexW4366995816

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.