Evidence map›Paper›PMID 37096210›Full record

ArticleACS photonics2023

Simultaneous Widefield Voltage and Dye-Free Optical Mapping Quantifies Electromechanical Waves in Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes.

Wei Liu, Julie L Han, Jakub Tomek, Gil Bub, Emilia Entcheva

Open access · hybridAbstract read
In one paragraph

Article in ACS photonics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Wei LiuDepartment of Biomedical Engineering, George Washington University, Washington, D.C. 20052, United States.ORCID https://orcid.org/0000-0002-1727-6738
Julie L HanDepartment of Biomedical Engineering, George Washington University, Washington, D.C. 20052, United States.
Jakub TomekDepartment of Pharmacology, University of California-Davis, Davis, California 95616, United States.
Gil BubDepartment of Physiology, McGill University, Montréal, Québec H3G 1Y6, Canada.
Emilia EntchevaDepartment of Biomedical Engineering, George Washington University, Washington, D.C. 20052, United States.ORCID https://orcid.org/0000-0002-6251-3376
George Washington University · USMcGill University · CAUniversity of California, Davis · US

Funding

Scalable platform for optimizing human cardiac tissue engineering via optical pacing and on-demand oxygenationR01HL144157 · NHLBI · GEORGE WASHINGTON UNIVERSITY · PI ENTCHEVA, EMILIA, KAY, MATTHEW W. · 2019 to 2022
$2.8M
Low-intensity ultrasound for control of cardiac electromechanics: a mechanistic investigation.R21EB026152 · NIBIB · GEORGE WASHINGTON UNIVERSITY · PI ENTCHEVA, EMILIA, ZDERIC, VESNA · 2018 to 2019
$439k
NHLBI NIH HHS R01 HL144157NIBIB NIH HHS R21 EB026152
6 · The paper itself

Abstract

Coupled electromechanical waves define a heart's function in health and diseases. Optical mapping of electrical waves using fluorescent labels offers mechanistic insights into cardiac conduction abnormalities. Dye-free/label-free mapping of mechanical waves presents an attractive non-invasive alternative. In this study, we developed a simultaneous widefield voltage and interferometric dye-free optical imaging methodology that was used as follows: (1) to validate dye-free optical mapping for quantification of cardiac wave properties in human iPSC-cardiomyocytes (CMs); (2) to demonstrate low-cost optical mapping of electromechanical waves in hiPSC-CMs using recent near-infrared (NIR) voltage sensors and orders of magnitude cheaper miniature industrial CMOS cameras; (3) to uncover previously underexplored frequency- and space-varying parameters of cardiac electromechanical waves in hiPSC-CMs. We find similarity in the frequency-dependent responses of electrical (NIR fluorescence-imaged) and mechanical (dye-free-imaged) waves, with the latter being more sensitive to faster rates and showing steeper restitution and earlier appearance of wavefront tortuosity. During regular pacing, the dye-free-imaged conduction velocity and electrical wave velocity are correlated; both modalities are sensitive to pharmacological uncoupling and dependent on gap-junctional protein (connexins) determinants of wave propagation. We uncover the strong frequency dependence of the electromechanical delay (EMD) locally and globally in hiPSC-CMs on a rigid substrate. The presented framework and results offer new means to track the functional responses of hiPSC-CMs inexpensively and non-invasively for counteracting heart disease and aiding cardiotoxicity testing and drug development.