Evidence map›Paper›PMID 37095887›Full record

ArticlePhotoacoustics2023

Detection of clot formation & lysis

Filip J Bodera, Mark J McVey, Krishnan Sathiyamoorthy, Michael C Kolios

Abstract read
In one paragraph

Article in Photoacoustics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Filip J BoderaDepartment of Physics, Toronto Metropolitan University, Toronto, Canada.
Mark J McVeyDepartment of Physics, Toronto Metropolitan University, Toronto, Canada.
Krishnan SathiyamoorthyDepartment of Physics, Toronto Metropolitan University, Toronto, Canada.
Michael C KoliosDepartment of Physics, Toronto Metropolitan University, Toronto, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Clotting is a physiological process that prevents blood loss after injury. An imbalance in clotting factors can lead to lethal consequences such as exsanguination or inappropriate thrombosis. Clinical methods to monitor clotting and fibrinolysis typically measure the viscoelasticity of whole blood or optical density of plasma over time. Though these methods provide insights into clotting and fibrinolysis, they require milliliters of blood which can worsen anemia or only provide partial information. To overcome these limitations, a high-frequency photoacoustic (HFPA) imaging system was developed to detect clotting and lysis in blood. Clotting was initiated in vitro in reconstituted blood using thrombin and lysed with urokinase plasminogen activator. Frequency spectra measured using HFPA signals (10-40 MHz) between non-clotted blood and clotted blood differed markedly, allowing tracking of clot initiation and lysis in volumes of blood as low as 25 µL/test. HFPA imaging shows potential as a point-of-care examination of coagulation and fibrinolysis.

Indexed as

BloodClotFrequencyImagingIn-VitroLysisPAPhotoacoustic

Identifiers

PMID37095887
PMCPMC10122060

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.