Determining the quality control frequency of an MR-linac using risk matrix (RM) analysis.

Min Ma, Hui Yan, Minghui Li, Yuan Tian, Ke Zhang, Kuo Men, Jianrong Dai

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Min MaNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Hui YanNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Minghui LiNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Yuan TianNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Ke ZhangNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.ORCID https://orcid.org/0000-0002-9977-4166
Kuo MenNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Jianrong DaiNational Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Funding

National Natural Science Foundation of China 11875320National Natural Science Foundation of China 11975312
6 · The paper itself

Abstract

purposeQuality control (QC) is performed routinely through professional guidelines. However, the recommended QC frequency may not be optimal among different institutional settings. Here we propose a novel method for determining the optimal QC frequency using risk matrix (RM) analysis. METHODS AND MATERIALS: A newly installed Magnetic Resonance linac (MR-linac) was chosen as the testing platform and six routine QC items were investigated. Failures of these QC items can adversely affect treatment outcome for the patient. Accordingly, each QC item with its assigned frequency forms a unique failure mode (FM). Using FM-effect analysis (FMEA), the severity (S), occurrence (O), and detection (D) of each FM was obtained. Next, S and D based on RM was used to determine the appropriate QC frequency. Finally, the performance of new frequency for each QC item was evaluated using the metric E = O/D.

resultsOne new QC frequency was the same as the old frequency, two new QC frequencies were less than the old ones, and three new QC frequencies were higher than the old ones. For six QC items, E values at the new frequencies were not less than their values at the old frequencies. This indicates that the risk of machine failure is reduced at the new QC frequencies.

conclusionsThe application of RM analysis provides a useful tool for determining the optimal frequencies for routine linac QC. This study demonstrated that linac QC can be performed in a way that maintains high performance of the treatment machine in a radiotherapy clinic.

Indexed as

Magnetic Resonance ImagingHumansMagnetic Resonance SpectroscopyQuality ControlRisk Assessmentfailure mode and effect analysisfrequencyquality controlrisk matrix

Identifiers

PMID37095706
PMCPMC10402679

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.