ArticleJournal of applied clinical medical physics2023
Determining the quality control frequency of an MR-linac using risk matrix (RM) analysis.
Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Determining the quality control frequency of an MR-linac using risk matrix (RM) analysis.Journal of applied clinical medical physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeQuality control (QC) is performed routinely through professional guidelines. However, the recommended QC frequency may not be optimal among different institutional settings. Here we propose a novel method for determining the optimal QC frequency using risk matrix (RM) analysis. METHODS AND MATERIALS: A newly installed Magnetic Resonance linac (MR-linac) was chosen as the testing platform and six routine QC items were investigated. Failures of these QC items can adversely affect treatment outcome for the patient. Accordingly, each QC item with its assigned frequency forms a unique failure mode (FM). Using FM-effect analysis (FMEA), the severity (S), occurrence (O), and detection (D) of each FM was obtained. Next, S and D based on RM was used to determine the appropriate QC frequency. Finally, the performance of new frequency for each QC item was evaluated using the metric E = O/D.
resultsOne new QC frequency was the same as the old frequency, two new QC frequencies were less than the old ones, and three new QC frequencies were higher than the old ones. For six QC items, E values at the new frequencies were not less than their values at the old frequencies. This indicates that the risk of machine failure is reduced at the new QC frequencies.
conclusionsThe application of RM analysis provides a useful tool for determining the optimal frequencies for routine linac QC. This study demonstrated that linac QC can be performed in a way that maintains high performance of the treatment machine in a radiotherapy clinic.