Evidence map›Paper›PMID 37095316›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

An adaptable research platform for ex vivo normothermic machine perfusion of the liver.

M Magbagbeola, Z L Rai, K Doyle, L Lindenroth, G Dwyer, A Gander, A Stilli, B R Davidson, D Stoyanov

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

M MagbagbeolaWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK. morenike.magbagbeola.16@ucl.ac.uk.ORCID http://orcid.org/0000-0002-2266-2545
Z L RaiWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
K DoyleWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
L LindenrothDepartment of Surgical and Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
G DwyerWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
A GanderCentre for Surgical Innovation, Organ Repair and Transplantation (CSIORT), UCL, London, UK.
A StilliWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
B R DavidsonWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
D StoyanovWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
Wellcome / EPSRC Centre for Interventional and Surgical Sciences · GBThe Royal Free Hospital · GBKing's College London · GB

Funding

Wellcome Trust
6 · The paper itself

Abstract

purposeThis paper presents an assessment of a low-cost organ perfusion machine designed for use in research settings. The machine is modular and versatile in nature, built on a robotic operating system (ROS2) pipeline allowing for the addition of specific sensors for different research applications. Here we present the system and the development stages to achieve viability of the perfused organ.

methodsThe machine's perfusion efficacy was assessed by monitoring the distribution of perfusate in livers using methylene blue dye. Functionality was evaluated by measuring bile production after 90 min of normothermic perfusion, while viability was examined using aspartate transaminase assays to monitor cell damage throughout the perfusion. Additionally, the output of the pressure, flow, temperature, and oxygen sensors was monitored and recorded to track the health of the organ during perfusion and assess the system's capability of maintaining the quality of data over time.

resultsThe results show the system is capable of successfully perfusing porcine livers for up to three hours. Functionality and viability assessments show no deterioration of liver cells once normothermic perfusion had occurred and bile production was within normal limits of approximately 26 ml in 90 min showing viability.

conclusionThe developed low-cost perfusion system presented here has been shown to keep porcine livers viable and functional ex vivo. Additionally, the system is capable of easily incorporating several sensors into its framework and simultaneously monitor and record them during perfusion. The work promotes further exploration of the system in different research domains.

Indexed as

Liver TransplantationAnimalsLiverOrgan PreservationPerfusionSwineTemperatureLiver preservationMachine perfusionSystems design

Identifiers

PMID37095316
PMCPMC10284990
OpenAlexW4366816620

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.