Evidence map›Paper›PMID 37092528›Full record

ArticleOrthopaedic surgery2023

Relationship of Pelvic Positional Change with Leg Length and Offset Measurement in Experimental Total Hip Arthroplasty.

Naoya Kikuchi, Haruo Kawamura, Tomofumi Nishino, Hajime Mishima

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Naoya KikuchiDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.ORCID https://orcid.org/0000-0001-7282-5878
Haruo KawamuraDepartment of Orthopaedic Surgery, North Prefecture Medical Center, Takahagi Kyodo Hospital, 1006-9 Agehocho, Kamitetsuna, Takahagi, Ibaraki, 318-0004, Japan.
Tomofumi NishinoDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Hajime MishimaDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
University of Tsukuba · JPNational Hospital Organization Takamatsu Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveDuring total hip arthroplasty (THA), both pelvic and femur positions affect leg length (LL) and offset (OS) measurements because LL and OS calipers depend on the fixed reference points on the pelvis and femur, respectively. However, LL and OS measurement errors because of pelvic positional changes have not been described. This study aimed to clarify the effects of pelvic positional changes on LL and OS measurements in relation to the pelvic reference using a THA simulator.

methodsWe developed an experimental THA simulator using Sawbones models of the hemipelvis and femur that facilitated modification of the obliquity, tilt, and rotation of the pelvis. Using an LL and OS caliper, LL and OS measurement errors due to pelvic positional changes were determined with the femoral position fixed. Measurements were performed from two pelvic reference positions: the iliac tubercle (P1) and the top of the iliac crest intersecting the line of the femoral long axis (P2).

resultsConcerning pelvic obliquity, the total error of LL was 25.0 mm in P1 and 26.5 mm in P2, while the total error of OS was 13.0 mm in P1 and 10.9 mm in P2. For pelvic tilt, the total error of LL was 9.0 mm in P1 and 3.8 mm in P2, while the total error of OS was 0.5 mm in P1 and 1.0 mm in P2. Regarding pelvic rotation, the total error of LL was 13.8 mm in P1 and 3.2 mm in P2, while the total error of OS was 3.8 mm in P1 and 4.0 mm in P2.

conclusionsPelvic positional changes alter LL and OS measurements. The acceptable range (error <2 mm) on LL and OS measurement errors of pelvic obliquity was only 2°, regardless of the pelvic reference position. The pelvic reference position should be at the top of the iliac crest intersecting the line of the long axis of the femur because of a small LL measurement error with pelvic tilt and rotation.

Indexed as

Arthroplasty, Replacement, HipBone DiseasesFemurHumansLegLower ExtremityPelvisLeg LengthOffsetPelvic positionTotal hip arthroplasty

Identifiers

PMID37092528
PMCPMC10235182
OpenAlexW4366822086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.