Evidence map›Paper›PMID 37091441›Full record

ArticleIndian journal of anaesthesia2023

Comparison of oropharyngeal leak pressure of LMA Protector and LMA-ProSeal in different head and neck positions in anaesthetized and paralyzed patients; A prospective randomized study.

Sukhyanti Kerai, Garima Bhatt, Kirti N Saxena, Prachi Gaba, Bharti Wadhwa

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of anaesthesia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Sukhyanti KeraiDepartment of Anaesthesiology and Intensive Care, Maulana Azad Medical College and Associated Hospitals, New Delhi, India.
Garima BhattDepartment of Anaesthesiology and Intensive Care, Maulana Azad Medical College and Associated Hospitals, New Delhi, India.
Kirti N SaxenaDepartment of Anaesthesiology and Intensive Care, Maulana Azad Medical College and Associated Hospitals, New Delhi, India.
Prachi GabaDepartment of Anaesthesiology and Intensive Care, Maulana Azad Medical College and Associated Hospitals, New Delhi, India.
Bharti WadhwaDepartment of Anaesthesiology and Intensive Care, Maulana Azad Medical College and Associated Hospitals, New Delhi, India.
Creative Commons · USMaulana Azad Medical College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Oropharyngeal leak pressure (OLP) of LMA Protector is reported to be higher compared to other second generation supraglottic devices (SGDs) indicating better seal with patient's airway and hence enhanced safety. To ascertain its benefit in patients undergoing surgeries where head and neck position other than neutral is required, we conducted a prospective randomized study to compare OLP of LMA Protector with LMA-ProSeal (PLMA) with head and neck in neutral, extension, flexion, and rotation position. Methods: 80 American Society of Anesthesiologists (ASA) I-II patients aged more than 18 years undergoing elective surgery under general anaesthesia were recruited. Patients were randomized in the LMA Protector or PLMA group. After induction of anaesthesia, OLP was measured in both the groups in different head and neck position. The insertion characteristics of both SGDs were also recorded and compared. Results: The OLP of LMA Protector and PLMA was found to be comparable in neutral head position (p = 0.08). There was no significant difference in OLP of both devices in extension, flexion, or head rotation. In both the study groups, head extension position led to significant decrease in OLP compared to supine position. With the flexion and rotation positioning of head and neck, significant increase in OLP in each group was noted. Conclusion: The OLP of LMA Protector and PLMA are comparable in different head and neck position. With both the devices, there was significant decrease in OLP with extension whereas significant increase was noted in flexion and rotation of head and neck.

Indexed as

Airwayanesthesiahead and necklaryngeal maskposition

Identifiers

PMID37091441
PMCPMC10121088
OpenAlexW4320924036

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.