ArticleEsophagus : official journal of the Japan Esophageal Society2023
Patient adverse events and technical failures with the bravo capsule pH system: insights from the MAUDE database.
Article in Esophagus : official journal of the Japan Esophageal Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Analysis of Reported Adverse Events Associated with Sphincterotomes: An FDA Manufacturer and User Facility Device Experience (MAUDE) Database Study.Digestive diseases and sciences · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe BRAVO pH monitor system can benefit patients with ongoing GERD symptoms despite treatment and/or atypical symptoms. We aim to investigate the number and type of complications associated with the BRAVO pH capsule.
methodsFrom April 2016 through February 2021, we analyzed post-marketing surveillance data from the FDA Manufacturer and User Facility Device Experience (MAUDE) database.
resultsDuring the study period, approximately 1,651 reports were identified with 2391 cases associated with a device failure, and 254 reporting a patient-related adverse event. Most device complications were due to aspiration n = 153), followed by reported pain (n = 79), injury (unspecified) (n = 63), and additional radiologic imaging (n = 44). Laceration and bleeding accounted for 29 and 19 cases. Furthermore, three patients suffered perforation. Most device failures were due to loss or failure of the Bravo capsule to bond or adhere to the esophageal mucosa as planned (n = 1269), followed by an activation or positioning failure (n = 972), premature detachment of device (n = 284), and failure of the device to record or transmit data (n = 158).
conclusionsFindings from the MAUDE database highlight the risk of aspiration, hemorrhage/bleeding, perforation, injury, and retention as potential complications of BRAVO capsule placement.
Indexed as
Identifiers
37084162What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.