Biomechanical testing of a modified knotless transscleral suture fixation technique: an

Pusheng Xu, Xuepei Li, Zongwen Ke, Charlotte Young, Zhangkai Lian, Guangming Jin, Danying Zheng

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Transscleral suture fixation in congenital ectopia lentis.Annals of translational medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Pusheng Xu *State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Xuepei Li *State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Zongwen KeState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Charlotte YoungDepartment of Ophthalmology, Third Affiliated Hospital, Nanchang University, Nanchang, China.
Zhangkai LianState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Guangming JinState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Danying ZhengState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.
Sun Yat-sen University · CNThird Affiliated Hospital of Nanchang University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: To investigate the safety and effectiveness of a modified transscleral suture through Methods: Results: The average minimum traction forces required to loosen 10-0 polypropylene sutured for 3.0 mm with a suture span of 3, 4, and 5 passes, were 0.18 (0.15-0.18), 0.22 (0.21-0.22), and 0.37 (0.37-0.37) N, respectively. The maximum traction force to prevent the suture from rupturing for the 10-0 polypropylene suture was 0.37-0.41 N in the sclera. The average of the minimum traction forces required to loosen the 8-0 polypropylene sutured with 5 passes and spanning 2.0, 3.0, and 4.0 mm were 0.37 (0.3 -0.39), 0.42 (0.42-0.45), and 0.50 (0.50-0.51) N, respectively, which were 14-28% higher than that of the 10-0 polypropylene suture under same conditions (all P values <0.01). In addition, there was no statistical difference (P=0.3258) for the 8-0 polypropylene suture used with a 3.0-mm suture span and 5 passes between conditions with or without scleral grooves. Conclusions: The minimum traction force required to loosen or rupture the suture in the sclera was associated with suture specification, suture span, and the number of passes, but was uncorrelated with double scleral grooves. The 8-0 polypropylene suture with double scleral grooves may be a more favorable choice for knotless transscleral fixation.

Indexed as

Biomechanical testmodified surgerytransscleral fixationZ-suture