Evidence map›Paper›PMID 37082629›Full record

ArticleHeliyon2023

Modified Fukuda stepping motion assessment of young healthy adults using portable inertial measurement units.

Toru Miwa, Tomohisa Yasuda, Teppei Kouga, Kishiko Sunami

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Toru MiwaDepartment of Otolaryngology-Head and Neck Surgery, Osaka Metropolitan University, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan.
Tomohisa YasudaYasuda ENT Clinic, 1-1-1 Takaramachi, Katsusika-ku, Tokyo 124-0005, Japan.
Teppei KougaDepartment of Otolaryngology-Head and Neck Surgery, Osaka Metropolitan University, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan.
Kishiko SunamiDepartment of Otolaryngology-Head and Neck Surgery, Osaka Metropolitan University, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan.
Osaka Metropolitan University · JPKyoto University · JPTakara (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Currently, vestibular rehabilitation approaches used to monitor body position and movement during rehabilitation training require specialized equipment or rely on clinician observation. Thus, a simpler position-sensing approach that can be used to monitor movement during vestibular rehabilitation is required. This study used wearable motion sensors with built-in accelerometers and gyrometers to assess movement in adults. We explored stepping patterns in adults using this motion-sensing system. Six healthy adults (men, age 27.3 ± 5.8 years) underwent a modified Fukuda stepping test (Foulage test [FT]) while wearing a six-axis motion sensor (accelerometer: X-axis, Y-axis, Z-axis; gyrometer: X-axis, Y-axis, Z-axis) positioned at the head, thorax, and lumbar spine. For motion sensor parameters, we calculated the root mean square (RMS), autocorrelation coefficient (AC), power spectrum (PS) of the AC, and Euler angles from the six-axis motion sensor. For the FT parameters, the FT value, step variance, and θ values were calculated. Data were analyzed, and multivariable regression analysis was performed using the FT value, step variance, and θ value as the dependent variables to investigate their influence on dynamic equilibrium. The explanatory variables included the motion sensor parameters, RMS, AC, and PS. Our results suggested that almost no head and lumbar spine movement occurred while stepping with eyes open. Contrastingly, the head and lumbar spine swayed with eyes closed. This accelerometric and gyroscopic device is easy to use, does not require specialized equipment, and can be used to analyze performance in the modified Fukuda stepping test in clinical practice. Inertial sensors have many advantages over other sensing technologies.

Indexed as

Foulage testInertial measurement unitMicro-electromechanical systemModified fukuda stepping testMultivariable regression analysisSensing technologiesSix-axis motion sensor

Identifiers

PMID37082629
PMCPMC10112030
OpenAlexW4361264450

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.