Evidence map›Paper›PMID 37082218›Full record

ArticleFrontiers in bioengineering and biotechnology2023

Liquid metal integrated PU/CNT fibrous membrane for human health monitoring.

Mei-Xi Li, Da-Yong Wu, Rong-Yu Tang, Si-Yuan Zhou, Wei-Hua Liang, Jing Liu, Lei Li

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Mei-Xi LiTechnical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
Da-Yong WuTechnical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
Rong-Yu TangThe State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, China.
Si-Yuan ZhouTechnical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
Wei-Hua LiangTechnical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
Jing LiuKey Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
Lei LiKey Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China.
University of Chinese Academy of Sciences · CNTechnical Institute of Physics and Chemistry · CNChinese Academy of Sciences · CNInstitute of Semiconductors · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable flexible sensors are widely used in several applications such as physiological monitoring, electronic skin, and telemedicine. Typically, flexible sensors that are made of elastomeric thin-films lack sufficient permeability, which leads to skin inflammation, and more importantly, affects signal detection and consequently, reduces the sensitivity of the sensor. In this study, we designed a flexible nanofibrous membrane with a high air permeability (6.10 mm/s), which could be effectively used to monitor human motion signals and physiological signals. More specifically, a flexible membrane with a point (liquid metal nanoparticles)-line (carbon nanotubes)-plane (liquid metal thin-film) multiscale conductive structure was fabricated by combining liquid metal (LM) and carbon nanotubes (CNTs) with a polyurethane (PU) nanofibrous membrane. Interestingly, the excellent conductivity and fluidity of the liquid metal enhanced the sensitivity and stability of the membrane. More precisely, the gauge factor (GF) values of the membrane is 3.0 at 50% strain and 14.0 at 400% strain, which corresponds to a high strain sensitivity within the whole range of deformation. Additionally, the proposed membrane has good mechanical properties with an elongation at a break of 490% and a tensile strength of 12 MPa. Furthermore, the flexible membrane exhibits good biocompatibility and can efficiently monitor human health signals, thereby indicating potential for application in the field of wearable electronic devices.

Indexed as

carbon nanotubeselectrospinninghuman health monitoringliquid metalmultiscale conductive structure

Identifiers

PMID37082218
PMCPMC10111225
OpenAlexW4362520054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.