Evidence map›Paper›PMID 37081513›Full record

ArticleJournal of neuroengineering and rehabilitation2023

Quantitative assessments of finger individuation with an instrumented glove.

Brian J Conway, Léon Taquet, Timothy F Boerger, Sarah C Young, Kate B Krucoff, Brian D Schmit, Max O Krucoff

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Brian J ConwayMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA. brianjconway51@gmail.com.ORCID 0000-0002-2563-0661
Léon TaquetMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.
Timothy F BoergerMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.ORCID 0000-0003-1587-3704
Sarah C YoungMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.
Kate B KrucoffMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.
Brian D SchmitDepartment of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA.
Max O KrucoffMedical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn clinical and research settings, hand dexterity is often assessed as finger individuation, or the ability to move one finger at a time. Despite its clinical importance, there is currently no standardized, sufficiently sensitive, or fully objective platform for these evaluations.

methodsHere we developed two novel individuation scores and tested them against a previously developed score using a commercially available instrumented glove and data collected from 20 healthy adults. Participants performed individuation for each finger of each hand as well as whole hand open-close at two study visits separated by several weeks. Using the three individuation scores, intra-class correlation coefficients (ICC) and minimal detectable changes (MDC) were calculated. Individuation scores were further correlated with subjective assessments to assess validity.

resultsWe found that each score emphasized different aspects of individuation performance while generating scores on the same scale (0 [poor] to 1 [ideal]). These scores were repeatable, but the quality of the metrics varied by both equation and finger of interest. For example, index finger intra-class correlation coefficients (ICC's) were 0.90 (< 0.0001), 0.77 (< 0.001), and 0.83 (p < 0.0001), while pinky finger ICC's were 0.96 (p < 0.0001), 0.88 (p < 0.0001), and 0.81 (p < 0.001) for each score. Similarly, MDCs also varied by both finger and equation. In particular, thumb MDCs were 0.068, 0.14, and 0.045, while index MDCs were 0.041, 0.066, and 0.078. Furthermore, objective measurements correlated with subjective assessments of finger individuation quality for all three equations (ρ = - 0.45, p < 0.0001; ρ = - 0.53, p < 0.0001; ρ = - 0.40, p < 0.0001).

conclusionsHere we provide a set of normative values for three separate finger individuation scores in healthy adults with a commercially available instrumented glove. Each score emphasizes a different aspect of finger individuation performance and may be more uniquely applicable to certain clinical scenarios. We hope for this platform to be used within and across centers wishing to share objective data in the physiological study of hand dexterity. In sum, this work represents the first healthy participant data set for this platform and may inform future translational applications into motor physiology and rehabilitation labs, orthopedic hand and neurosurgery clinics, and even operating rooms.

Indexed as

FingersIndividuationAdultHandHumansUpper ExtremityCybergloveFinger individuationHand dexterityKinematicsMotor systemsNeuro-engineeringNeurophysiology

Identifiers

PMID37081513
PMCPMC10120262

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked