Highly sensitive low-frequency-detectable acoustic sensor using a piezoresistive cantilever for health monitoring applications.

Yuki Okamoto, Thanh-Vinh Nguyen, Hidetoshi Takahashi, Yusuke Takei, Hironao Okada, Masaaki Ichiki

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuki OkamotoNational Institute of Advanced Industrial Science and Technology (AIST), Sensing System Research Center, Tsukuba, 305-8564, Japan. yuki.okamoto@aist.go.jp.
Thanh-Vinh NguyenNational Institute of Advanced Industrial Science and Technology (AIST), Sensing System Research Center, Tsukuba, 305-8564, Japan.
Hidetoshi TakahashiDepartment of Mechanical Engineering, Keio University, Yokohama, 223-8522, Japan.
Yusuke TakeiNational Institute of Advanced Industrial Science and Technology (AIST), Sensing System Research Center, Tsukuba, 305-8564, Japan.
Hironao OkadaNational Institute of Advanced Industrial Science and Technology (AIST), Sensing System Research Center, Tsukuba, 305-8564, Japan.
Masaaki IchikiNational Institute of Advanced Industrial Science and Technology (AIST), Sensing System Research Center, Tsukuba, 305-8564, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigates a cantilever-based pressure sensor that can achieve a resolution of approximately 0.2 mPa, over the frequency range of 0.1-250 Hz. A piezoresistive cantilever with ultra-high acoustic compliance is used as the sensing element in the proposed pressure sensor. We achieved a cantilever with a sensitivity of approximately 40 times higher than that of the previous cantilever device by realizing an ultrathin (340 nm thick) structure with large pads and narrow hinges. Based on the measurement results, the proposed pressure sensor can measure acoustic signals with frequencies as low as 0.1 Hz. The proposed pressure sensor can be used to measure low-frequency pressure and sound, which is crucial for various applications, including photoacoustic-based gas/chemical sensing and monitoring of physiological parameters and natural disasters. We demonstrate the measurement of heart sounds with a high SNR of 58 dB. We believe the proposed microphone will be used in various applications, such as wearable health monitoring, monitoring of natural disasters, and realization of high-resolution photoacoustic-based gas sensors. We successfully measured the first (S1) and second (S2) cardiac sounds with frequencies of 7-100 Hz and 20-45 Hz, respectively.

Indexed as

Heart SoundsNatural DisastersAcousticsSound